      Home> Fineness Gauge> Moderner> Moderner QXD-50 (large double-channel) Large double-channel Fineness gauge

      MODERNER QXD-50 Large double-channel Fineness gauge measurement range 0~50μm

      The QXD 50 large double-channel Fineness gauge is a large double-channel Fineness gauge with a chute width of 25.4mm. The QXD 50 has a Fineness measurement range of 0 to 50 microns and a Graduation of 5 microns. It is widely used in Paints, varnishes, Printing ink and other materials for the fineness of grinding.

      Brand
      SKU: NB000764
      China Moderner
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner QXD-50 (large double-channel) Large double-channel Fineness gaugeOverview

        • Specifications
        • Comments
        • FAQs
        QXD-50 (large double-channel)
        Large double-channel Fineness gauge

        overview

        QXD 50 large double-slot Fineness of Grind Gauge is a large double-slot Fineness of Grind Gauge with a chute width of 25.4mm. The fineness measurement range of QXD 50 is 0~50 microns, and the division value is 5 microns.

        In the MODERNER, there are various specifications for the research and development and design of the Fineness of Grind Gauge, including general single and double grooves, wide grooves, and large and wide grooves. This large double-slot Fineness of Grind Gauge is a Fineness of Grind Gauge with a large chute width. There are two models, QXD 25 and QXD 50. The corresponding measuring ranges are 0~25 microns and 0~50 microns respectively. The design has Two wider chute with a width of 5.4mm. Applicable to some users with special needs.

        The large double-slot fineness scraper QXD 25/50 conforms to the national standard and is mainly used to measure the fineness of particles such as pigments and impurities in paints and paint pastes. The large double-groove fineness scraper is made of stainless steel, and it is equipped with a 95mm scraper. The width of the chute is larger than that of the general fineness plate. The fineness scraper is designed and manufactured according to JJG (Chemical) 018-96 "Grindometer" and its GB/T1724 standard of the Ministry of Chemical Industry of the People's Republic of CHINA for the verification of special equipment for coatings.

        Features

        1) QXD 50 large double-slot Fineness of Grind Gauge is widely used in the determination of the grinding fineness of paint, varnish, printing ink and other materials

        2) The fineness is expressed in microns (μm) or Hegman grades (Hegman)

        3) Compliance with standards: GB/T 1724, GB/T 13217.3, ISO 1524, ASTM D1210

        4) QXD 50 large double-slot Fineness of Grind Gauge is made of stainless steel

        real shot

        QXD large double groove Fineness of Grind Gauge material description

        Description of QXD large double-slot scraper fineness measurement range and sub-scale

        Instructions for the use of QXD large double-slot Fineness of Grind Gauge

        Steps for usage

        (1) Before use, the QXD 50 Fineness of Grind Gauge should be soaked with a suitable solvent, including the scraper and the bottom, and dried with cotton yarn, and the sample that meets the product standard viscosity index should be fully stirred with a paint knife.

        (2) In the deepest part of the groove of the QXD 50 large double-groove Fineness of Grind Gauge , drop a few drops of the sample, which can fill the groove and be slightly redundant.

        (3) Hold the scraper with the thumb, index, and middle fingers of both hands. Place it horizontally on the upper end of the double-groove Grindometer, make the scraper perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed, so that the paint sample fills the groove without leaving any residue on the plate. There is excess paint.

        (4) Immediately (not more than 5 seconds) after scraping, pinch the fineness gauge horizontally and tilt it so that the line of sight is 15-30° from the groove plane and observe the scale value of the uniformly exposed particles in the groove. The reading value is The fineness value of the measured object.

        Precautions

        (1) Do not scratch the surface of the Grindometer and the scraper

        (2) Clean the QXD 50 large double-slot Grindometer immediately after use and apply Vaseline to prevent rust

        (3) When measuring the fineness, the clear oil that meets the product standard should be adjusted before measuring

        (4) Regularly (one year) check the knife edge and the straightness of the fineness gauge, and if it is found to be uneven or the Grindometer is worn, it needs to be calibrated by the national metrology and verification agency before it can be used.

        MODERNER Fineness of Grind Gauge series specification list

        MODERNER Fineness of Grind Gauge series specification list

        Series

        SpecificationRangeDivision valueGroove sizeunit
        small single slot0-150.7512.7*140μm
        0-251.25Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        small double slot0-252.5Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        wide slot0-251.2525.4*127Hegman/μm
        0-502.5
        0-1005
        large wide groove0-252.550.8*127
        0-505
        0-1005
        Big double slot0-252.525.4*165Hegman/μm/NPIRI
        0-505
        0-1005
        Special double slot0-502μm
        0-25010μm


        VS

        Moderner QXD-50 (large double-channel) Large double-channel Fineness gaugeSpecifications

        LIST VALUE
        Scraper type double-channel
        Number of grooves 2
        range 0 ~ 50µm
        Scale unit μm、Hegman
        Scraper material stainless steel
        Scraper size 241.3*88.9*19.05mm
        Groove size 25.4*165mm
        Scraper material stainless steel
        Scraper size 95mm
        Applicable standard GB/T 1724、GB/T 13217.3、ISO 1524、ASTM D1210
        Graduation 5μm

        Moderner QXD-50 (large double-channel) Large double-channel Fineness gauge Packing list

        Scraper x1, scraper x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        I don't know how much sample volume needs to be placed for this large slot width?
        [A]
        Fineness gauge does not say the amount of sample. When using, drop a few drops of the test sample into the deepest part of the groove of Fineness gauge to fill the groove and have a little excess to experiment.
        [Q]
        Can the MODERNER QXD50 Fineness gauge be used to scrape 11μm pigments?
        [A]
        Yes, the large double-channel scraper fineness Measurement can scrape 0~ 50μm or less material fineness.
        [Q]
        Can this Fineness gauge be applied to ASTMD1210-05?
        [A]
        OK
        [Q]
        Gravure plate Printing ink Fineness inspection which?
        [A]
        Gravure plate Printing ink can be selected from 0~ 50μm scraper Fineness meter (domestic Qxp-50), one path or 2 paths can be selected according to their own requirements. reference standard GB/T 13217.3
        [Q]
        How does the 2 paths scraper Fineness meter read?
        [A]
        Hello, you can take a look at our knowledge article "How to Read the Scraper Fineness Meter":/k/1875
        Moderner
        MODERNER QXD-50 Large double-channel Fineness gauge measurement range 0~50μm
        Service
        Focus on online sales of Lab Testing Instruments