SHINKO Shinko AB323C Electronic Balance accuracy 0.001g Weighing up to 320g
SHINKO Shinko AB323C Electronic Balance is a laboratory one thousandth Electronic Balance with external weight calibrated, AB323C Electronic Balance with backlit display.
Shinko-
HUAZHI DTT-A2000 Lab Balance 2000g/0.01g
$ 232.00 -
Electronic Balance Tianma TD60001 6000g/0.1g External Calibration
$ 239.00 -
AB125C Laboratory Analysis Electronic Balance 120g internal calibration
$ 3223.00 -
HUAZHI PTL-3kg (0.05/0) Industrial Electronic Balance Dual Range: 3kg/4kg
$ 270.00 -
JINGHAI FA1604N (internal calibration) Analytical balance 160g/0.1mg φ 80mm
$ 543.00
Introduction
Shinko Shinko AB323C electronic balance is an economical, high-precision laboratory electronic balance for laboratory and industrial use.AB323C electronic balance uses the tuning fork sensor MMTS (Mono-Metal Tuning-fork Sensor) to improve the measurement speed, stability and resolution of the electronic balance.
Product features
1. Backlit LCD display
2. The function of counting parts, the number of parts can be calculated
3. Measurement percentage display
4. Set the judgment between too heavy and too light
5. Weighing, 12 kinds of weighing unit selection, including g, ct, oz, lb, ozt, dwt, GN, tl (Hong Kong), tl (Taiwan), tl (Singapore, Malaysia), momme, tola.
6. Equipped with a Wind Shield
Presentation diagram





Shinko AB323C Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Weighing range | 0~320g |
| Readability | 1mg |
| Nonlinear error | ±0.003g |
| Repeatability Error | 0.001g |
| Adjustment | Externally calibrated |
| Stabilization time | 3s |
| Pan Size | Φ140mm |
| Net Weight of instrument | About 3.5kg |
| Dimension | 293 * 202 * 206Mm (with wind hood) |
| Interface | RS-232C |
Shinko AB323C Electronic Balance Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Electronic Balance Use and Common Misoperation
- Common faults of Electronic Balance and their treatment measures
- How to Choose & Use Electronic Balance
- Principle and Application of Electronic Analytical Balance
- Two Main Factors Affecting the Weighing Accuracy of Electronic Balance
- Electronic Balance Use Attention to Details Possible Misunderstandings
- How should Electronic Balances be verified and calibrated?
- Introduction to the new use of Electronic Balance
- How to improve the use of Electronic Balance?
- Electronic Balance measurement in three steps
- AbolishGB/T 5211.6-1985
- ActiveGB/T 27596-2001
- ActiveJB/T 7443-1994
- ActiveGB/T 26497-2011
- ActiveFZ/T 10020-2011
- ReplacedFZ/T 01081-2000


AB323C