SHINKO Shinko AB623C Electronic Balance Weighing up to 620g
AB623C One Thousand Electronic Balance is a laboratory electronic Analytical Balance from SHINKO Shinko in Japan, with a weighing accuracy of 0.001g. AB623C One Thousand Electronic Balance is equipped with a wind hood.
Shinko-
SDPTOP YP102N Electronic Balance Weighing analytical balance 100 g
$ 206.00 -
Shangtian Jingyi AE223 1/1000 Electronic Balance Digital Balance 220g/1mg
$ 644.00 -
AB524C Electronic Balance Analytical balance 520g/0.1mg
$ 2850.00 -
TIANMA FA2004XC 1/10,000 Experimental Electronic Balance External School Type 200g
$ 543.00 -
Electronic Balance Tianma TD1002C precision 0.01g range up to 100g
$ 114.00
Introduction
Shinko Shinko AB623C 1/1000 Electronic Balance is an economical, high-precision laboratory electronic balance with a Wind Shield for laboratory and industrial use.AB623C 1/1000 electronic balance adopts the tuning fork sensor MMTS (Mono-Metal Tuning-fork Sensor) to improve the measurement speed, stability and resolution of the electronic balance.
Product features
1. Backlit LCD display
2. The function of counting parts, the number of parts can be calculated
3. Measurement percentage display
4. Set the judgment between too heavy and too light
5. Weighing, 12 kinds of weighing unit selection, including g, ct, oz, lb, ozt, dwt, GN, tl (Hong Kong), tl (Taiwan), tl (Singapore, Malaysia), momme, tola.
6. Equipped with a Wind Shield
Presentation diagram





Shinko AB623C Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Weighing range | 0~620g |
| Readability | 1mg |
| Nonlinear error | ±0.004g |
| Repeatability Error | 0.001g |
| Adjustment | Externally calibrated |
| Stabilization time | 3.5s |
| Pan Size | Φ140mm |
| Net Weight of instrument | About 3.5kg |
| Dimension | 293 * 202 * 206Mm (with wind hood) |
| Interface | RS-232C |
Shinko AB623C Electronic Balance Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Electronic Balance Use and Common Misoperation
- Common faults of Electronic Balance and their treatment measures
- How to Choose & Use Electronic Balance
- Principle and Application of Electronic Analytical Balance
- Two Main Factors Affecting the Weighing Accuracy of Electronic Balance
- Electronic Balance Use Attention to Details Possible Misunderstandings
- How should Electronic Balances be verified and calibrated?
- Introduction to the new use of Electronic Balance
- How to improve the use of Electronic Balance?
- Electronic Balance measurement in three steps
- AbolishGB/T 5211.6-1985
- ActiveGB/T 27596-2001
- ActiveJB/T 7443-1994
- ActiveGB/T 26497-2011
- ReplacedFZ/T 01081-2000


AB623C





