Japan Vibra AJ-320E One thousandth Electronic Balance weighing up to 320g with Wind Shield
The Japanese Vibra AJ-320E One Thousand Electronic Balance can weigh up to 320g and is equipped with a windproof glass cover. The AJ-320E One Thousand Electronic Balance is suitable for use in laboratories, factories, jewelry stores and other fields.
Vibra-
XINYUN JA603N Analysis Electronic Balance 600g/1mg Internal calibration
$ 471.00 -
Tianma FA1004X Electronic Balance external calibration measurement accurate to 0.1mg
$ 444.00 -
FA3204C Electronic Balance Experiment Electronic analytical balance 320g/0.1mg
$ 1091.00 -
JINGQI JY5002 Electronic Balance 500g/10mg
$ 193.00 -
Shangtian Jingyi AE1003 1/1000 Electronic Balance Laboratory Balance 1000g/1mg
$ 1175.00
Introduction
The Japanese Vibra AJ-320E thousandths electronic balance is one0.001g-precision benchtop Electronic Analytical Balances,The weighing pan is roundIt is equipped with a Tuning Fork sensor with a backlit display.AJ-320E thousandths electronic balanceIt is easy to operate and highly accurate, and is suitable for measurement in laboratories, factories, jewelry stores, etc.




Vibra AJ-320E Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Weighing range | 0~320g |
| Readability | 1mg |
| Nonlinear error | ±0.001g |
| Repeatability Error | 0.001g |
| Adjustment | Externally calibrated |
| Stabilization time | 2.5s |
| Pan Size | Φ118mm |
| Interface | RS-232C |
| Measurement system | Tuning Fork Frequency System |
| tare Weight | Full scale range |
| monitor | Built-in LCD display |
Vibra AJ-320E Electronic Balance Packing list
Balance x1, manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Electronic Balance Use and Common Misoperation
- Common faults of Electronic Balance and their treatment measures
- How to Choose & Use Electronic Balance
- Principle and Application of Electronic Analytical Balance
- Electronic Balance basic working principle and FAQ maintenance
- Illustrated electronic analytical balance working principle and operation introduction in experiment
- Detailed analysis of the correct operation procedures of precision Electronic Balance
- Electronic Balance edge knife calibrating method analysis
- Balanced subtotals
- What are the general requirements for the balance room of laboratory precision electronic analytical balance?
- AbolishGB/T 5211.6-1985
- ActiveGB/T 27596-2001
- ActiveJB/T 7443-1994
- ActiveGB/T 26497-2011
- ActiveFZ/T 10020-2011
- ReplacedFZ/T 01081-2000


AJ-320E





