Japan Vibra AJ-420E One thousandth Electronic Balance weighing up to 420g with Wind Shield
The Japanese Vibra AJ-420E One Thousand Electronic Balance is a 0.001g laboratory electronic Analytical Balance with a tuning fork sensor. The AJ-420E One Thousand Electronic Balance is equipped with a Wind Shield.
Vibra-
TIANMA FA2204XC Precision Balance 220g
$ 582.00 -
JINGHAI FA2004N internal calibration Electronic Analytical Balance 200g/0.1mg φ 80mm
$ 543.00 -
JINGHAI YP2001N Precision Electronic Balance 2000g/0.1g
$ 133.00 -
Electronic Balance Tianma TD30001 3000g/0.1g External Calibration
$ 189.00 -
YUEPING YP6001 Precision Balance 600g/100mg Disc
$ 116.00
Introduction
The Japanese Vibra AJ-420E is one thousandth of an electronic balance0.001g-precision benchtop Electronic Analytical Balances,The weighing pan is roundIt is equipped with a Tuning Fork sensor with a backlit display.AJ-420E thousandths electronic balanceIt is easy to operate and highly accurate, and is suitable for measurement in laboratories, factories, jewelry stores, etc.




Vibra AJ-420E Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Weighing range | 0~420g |
| Readability | 1mg |
| Nonlinear error | ±0.001g |
| Repeatability Error | 0.001g |
| Adjustment | Externally calibrated |
| Stabilization time | 2s |
| Pan Size | Φ118mm |
| Interface | RS-232C |
| Measurement system | Tuning Fork Frequency System |
| Tare Range | Full scale range |
| monitor | Built-in LCD display |
Vibra AJ-420E Electronic Balance Packing list
Balance x1, manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Electronic Balance Use and Common Misoperation
- Common faults of Electronic Balance and their treatment measures
- How to Choose & Use Electronic Balance
- Principle and Application of Electronic Analytical Balance
- Electronic Balance basic working principle and FAQ maintenance
- Illustrated electronic analytical balance working principle and operation introduction in experiment
- Electronic Balance structure and application description
- Briefly describe the daily application and maintenance of Electronic Balance
- How does the laboratory choose the right precision Electronic Balance?
- Which two factors affect the accuracy of Electronic Balance weighing?
- AbolishGB/T 5211.6-1985
- ActiveGB/T 27596-2001
- ActiveJB/T 7443-1994
- ActiveGB/T 26497-2011
- ActiveFZ/T 10020-2011
- ReplacedFZ/T 01081-2000


AJ-420E





