        MikroTest S3
        McCourt platings Thickness Gauge

        Introduction

        The EPK MikroTest S3 measures the thickness of enamel, plastic, and rubber layers on steel.

        The MIKROTEST Coating Thickness Gauge measures the thickness of all non-magnetic coatings on steel (e.g. lacquer, powder coat, plastic, zinc, copper, tin and nickel). Fast, accurate and non-destructive, MICROTEST has been the most widely used instrument for the automatic determination of coating thickness for more than 30 years. Germany's "know-how" shows that it has the highest level of magnetic cladding Thickness Gauge in terms of process technology and precision.

        Apply standards

        EPK MikroTest S3McCourt Coated Thickness Gauges comply with DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards.

        Features

        MIKROTEST OPERATES FULLY AUTOMATICALLY. It has the following very good characteristics when in use:

        1) Automatic measurement will not occur misoperation;

        2) Simple setup and measurement;

        3No calibration required;

        4No batteries or other power sources are required;

        5Automatically report the thickness reading;

        6With a non-destructive probe, a little bit of measurement;

        7The metal armor is suitable for frequent outdoor operation and use, and is protected from mechanical impact;

        8Resistant to mechanical shock, acid and solvent corrosion;

        9The balancing device eliminates the influence of gravity and can accurately measure in any direction and in the tube.

        Pictures

        German EPK MikroTest S3 McCourt Coating Thickness Gauge Display

        Comparison of EPK MikroTest coating Thickness Gauge series

        ModelMeasuring rangeReadabilityMinimum measuring area diameterThe minimum radius is convex and concave mmMinimum thickness of the substrateSuitable for:
        MIKROTEST G 60-100μm1 μm or 5% reading20mm5mm;25mm0.5mmElectroplating layer on steel, iron, lacquer, enamel, plastic, rubber layer
        MIKROTEST F 60-1000μm5 μm or 5% reading30mm8mm;25mm0.5mm
        MIKROTEST S3 60.2-3mm5% reading30mm15mm;25mm1.0mm
        MIKROTEST S5 60.5-5mm5% reading50mm15mm;25mm1.0mm
        MIKROTEST S10 62.5-10mm5% reading50mm15mm;25mm2.0mm
        MIKROTEST S20 67.5-20mm5% reading100mm100mm;150mm7.0mm
        MIKROTEST NIFE50 60-50μm2 μm + 8% reading20mm10mm;25mm0.5mmNickel plating on iron
        MIKROTEST NI500-50um1 μm or 5% reading15mm5mm;25mm-Nickel plating on a non-ferromagnetic metal substrate
        MIKROTEST NI1000-100um1 μm or 5% reading15mm5mm;25mm-
        VS

        ElektroPhysik MikroTest S3 McCourt platings Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle mechanical
        Measurement range 200~3000μm
        Minimum measurement surface 30mm
        Minimum radius of curvature Convex 15mm; Concave 25mm
        thinnest substrate 1.0mm
        probe Integrated probe
        Calibrated Certificate none
        Calibrated mode No need to calibrate
        Unit display mm
        statistical function none
        icon function none
        Interface none
        Data storage none
        Power Supply No Power Supply or battery required
        Standards DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards
        Display screen dial
        Operating temperature -20~100℃
        Machine Weight 560G (including instrument case)
        Machine size 215*55*29mm

        ElektroPhysik MikroTest S3 McCourt platings Thickness Gauge Packing list

        MikroTest Thickness Gauge, Operating Instructions, Encasement Box

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the accuracy of this thickness gauge?
        [A]
        Hello, the measurement accuracy is 5% of the reading.
        [Q]
        How to calibrate EPK thickness gauge?
        [A]
        Hello, this thickness gauge does not need to be calibrated.
        [Q]
        Are there any GB/T13452.2 standard McCourt coated platings thickness gauge?
        [A]
        This EPK McCourt platings thickness gauge can be used!