Germany EPK MikroTest S5 McCourt coated platings Thickness Gauge, thickness measurement: 0.5~ 5mm
The German EPK MikroTest S5 McCourt coated platings Thickness Gauge is a mechanical coated platings Thickness Gauge with a thickness measurement range of 500~5000 μm. The MikroTest S5 McCourt coated platings Thickness Gauge is suitable for the measurement of the thickness of enamel, plastic and rubber layers on steel. The minimum measurement area is 50mm.
ElektroPhysik-
AMITTARI AC-112AS Coating Thickness Gauge 5 buttons
$ 343.00 -
Defelsko PosiTector 6000 F45S3 Film Thickness Gauge 45 ° micro probe
$ 1756.00 -
LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
$ 254.00 -
LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
$ 410.00 -
LEEB Probe N1 eddy Current Probe with leeb242 Coating Thickness Gauge
Login
Introduction
The German EPK MikroTest S5 McCourt Coated Thickness Gauge measures the thickness of enamel, plastic, and rubber layers on steel.
The MIKROTEST Coating Thickness Gauge measures the thickness of all non-magnetic coatings on steel (e.g. lacquer, powder coat, plastic, zinc, copper, tin and nickel). Fast, accurate and non-destructive, MICROTEST has been the most widely used instrument for the automatic determination of coating thickness for more than 30 years. Germany's "know-how" shows that it has the highest level of magnetic cladding Thickness Gauge in terms of process technology and precision.
Apply standards
EPK MikroTest S5McCourt Coated Thickness Gauges comply with DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards.
Features
MIKROTEST OPERATES FULLY AUTOMATICALLY. It has the following very good characteristics when in use:
1) Automatic measurement will not occur misoperation;
2) Simple setup and measurement;
3)No calibration required;
4)No batteries or other power sources are required;
5)Automatically report the thickness reading;
6)With a non-destructive probe, a little bit of measurement;
7)The metal armor is suitable for frequent outdoor operation and use, and is protected from mechanical impact;
8)Resistant to mechanical shock, acid and solvent corrosion;
9)The balancing device eliminates the influence of gravity and can accurately measure in any direction and in the tube.
Pictures

Comparison of EPK MikroTest coating Thickness Gauge series
| Model | Measuring range | Readability | Minimum measuring area diameter | The minimum radius is convex and concave mm | Minimum thickness of the substrate | Suitable for: |
| MIKROTEST G 6 | 0-100μm | 1 μm or 5% reading | 20mm | 5mm;25mm | 0.5mm | Electroplating layer on steel, iron, lacquer, enamel, plastic, rubber layer |
| MIKROTEST F 6 | 0-1000μm | 5 μm or 5% reading | 30mm | 8mm;25mm | 0.5mm | |
| MIKROTEST S3 6 | 0.2-3mm | 5% reading | 30mm | 15mm;25mm | 1.0mm | |
| MIKROTEST S5 6 | 0.5-5mm | 5% reading | 50mm | 15mm;25mm | 1.0mm | |
| MIKROTEST S10 6 | 2.5-10mm | 5% reading | 50mm | 15mm;25mm | 2.0mm | |
| MIKROTEST S20 6 | 7.5-20mm | 5% reading | 100mm | 100mm;150mm | 7.0mm | |
| MIKROTEST NIFE50 6 | 0-50μm | 2 μm + 8% reading | 20mm | 10mm;25mm | 0.5mm | Nickel plating on iron |
| MIKROTEST NI50 | 0-50um | 1 μm or 5% reading | 15mm | 5mm;25mm | - | Nickel plating on a non-ferromagnetic metal substrate |
| MIKROTEST NI100 | 0-100um | 1 μm or 5% reading | 15mm | 5mm;25mm | - |
ElektroPhysik MikroTest S5 McCourt platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | mechanical |
| Measurement range | 500~5000μm |
| margin of error | ±5% |
| Minimum measurement surface | 50mm |
| Minimum radius of curvature | Convex 15mm; Concave 25mm |
| thinnest substrate | 1.0mm |
| probe | Integrated probe |
| Calibrated Certificate | none |
| Calibrated mode | No need to calibrate |
| Unit display | mm |
| statistical function | none |
| icon function | none |
| Interface | none |
| Data storage | none |
| Power Supply | No Power Supply or battery required |
| Standards | DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards |
| Display screen | dial |
| Operating temperature | -20~100℃ |
| Machine Weight | 560G (including instrument case) |
| Machine size | 215*55*29mm |
| Packaging Dimensions | 235*185*46mm |
ElektroPhysik MikroTest S5 McCourt platings Thickness Gauge Packing list
MikroTest Thickness Gauge, Operating Instructions, Encasement Box
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the Thickness Gauges that can test the thickness of underwater coatings?
- Can the coating Thickness Gauge measure the thickness of pipes?
- McCourt Coating Thickness Gauge Learn about these advantages, you can't choose the wrong instrument!
- Precautions for the use of MiKroTest McCourt Mechanical Coating Thickness G6
- What are the coating Thickness Gauges suitable for measuring the thickness of the coating in explosion-proof occasions?
- Dry-film thickness measurement: magnetic and mechanical methods
- Key points for maintenance of coating Thickness Gauge
- Coating Testing Instruments Popular Products Atlas
- EPK Coating Thickness Gauge FAQ
- Introduction of Several New Coating Thickness Gauges and Coating Holiday Detectors
- ReplacedNF EN ISO 2808-2007
- Active 901-2021
- Active 10254-2022
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012
- ActiveGB 12441-2018
- ActiveGB 14907-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveGB/T 14907-2018
- AbolishGB 14907-2002
- ActiveISO 2808-2019
- ActiveGB 28374-2012
- ISO 2361-1982
- AbolishISO 2808-2007
- ZB 51004-1985
- AbolishGB/T 12441-1998
- AbolishGB/T 14907-1994
- ActiveGB/T 13452.2-2008
- AbolishGB/T 11374-1989


MikroTest S5