      Home> Viscosity Cup> AnDe> AnDe LND-2 (3#) ISO Cup
      AnDe LND-2 (3#) ISO Cup

      Ander LND-2 (3 #) No. 3 ISO cup with bracket Viscosity range 7~ 40cst

      Ender No. 3 ISO cup, model LND-2 (3 #), is a desktop ISO Flow Cup with a bracket, the Viscosity range is 7~ 40cst, and the No. 3 ISO cup conforms to the ISO2431 standard.

      Brand
      SKU: NB008026
      China AnDe
      Stock
      Loading…
      Price
      $ 189.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • AnDe LND-2 (3#) ISO CupOverview

        • Specifications
        • Comments
        • FAQs
        LND-2 (3#)
        ISO Cup

        Introduction

        Ander LND-2 (3#) No. 3 ISO cup has a measuring range of 7~40cst and is used to measure the viscosity of coatings, paints, inks, etc. The No. 3 ISO cup is equipped with a stand, which is a desktop ISO Viscosity Cup and complies with the ISO2431 standard.

        Pictures

        Ander LND-2 (3#) No. 3 ISO cup display picture 1

        Appearance of Ande LND-2 (3#) No. 3 ISO Cup

        VS

        AnDe LND-2 (3#) ISO CupSpecifications

        LIST VALUE
        Viscosity range 7~40cSt
        Flow hole diameter 3mm
        Cup body material copper
        Applicable standard ISO 2431
        Certificate without

        AnDe LND-2 (3#) ISO Cup Packing list

        ISO cup x1, bracket x1, manual x1, certificate x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is there an ASTMD5125 standard ISO cup?
        [A]
        This ANDE ISO cup is fine!
        [Q]
        Coating viscosity measured by flow cup method, must be at the specified temperature? If not according to the specified viscosity will have any impact?
        [A]
        Viscosity cup measurement generally has 3 variables, viscosity, outflow time and temperature. Temperature is specified in many viscosity measurement standards because temperature has a large impact on viscosity, and the change of viscosity with temperature may not be dominant, and any diluted material used to adjust viscosity may also change the rate of this change.
        [Q]
        What is the viscosity range of the No. 3 desktop flow cup?
        [A]
        Hello, the measurement range of the Ander No. 3 desktop flow cup is 7~ 40cst.
        AnDe
        Ander LND-2 (3 #) No. 3 ISO cup with bracket Viscosity range 7~ 40cst