KOSON KS-50T anchor pull-out instrument, anchor pull-out force instrument, pull-out force range 0~500KN
KOSON KS-50T bolt pulling instrument adopts digital display Sensors imported from Switzerland, the resolution is 0.01KN, and the central aperture of the cylinder of the KS-50T anchor pulling force instrument is 60mm.
KOSON-
KOSON KS-50T anchor pull-out instrument, anchor pull-out force instrument, pull-out force range 0~500KN
$ 809.00 -
KOSON KS-71G Integrated Rebar Scanner (English version) Range 1~ 185mm
$ 1016.00 -
Runjie RJ-10 (Φ6~ Φ20) anchor, specially equipped with RJ-10 anchor puller
$ 203.00 -
Runjie RJ-10 Anchor TensIon Meter, pulling force 0~100kN
$ 494.00 -
TIANDIXINGHUO XH-50T Staging Pressure Relief Electric Drawing Instrument, Bolt Tension Meter 500kN
$ 1338.00

Model: KS-50T/KS-60T/KS-100T
Application
KS-50-60-100T series bolt puller, also known as (Bolt TensIon Meter), is a product independently developed by Shijiazhuang KOSON Instrument Technology Co., Ltd. It is suitable for testing various bolts, anchor cables, steel bars, and planting bars , expansion bolts, chemical anchor bolts, railway spikes, and various anchor pullout resistance instruments and equipment can also be used for on-site pullout resistance testing (testing) of glass curtain walls. Units, universities, coal mines,, etc.) required testing instruments.
Instrument Introduction
KS-10T/20T/30T/50T/60T/100T type anchor puller is composed of manual pump, hollow hydraulic cylinder, digital display pressure gauge, high-pressure oil pipe with quick joint (3 meters), optional accessories (anchor , conversion joint, pull rod) and portable carrying case, 10T ~ 30T ton hydraulic cylinder is hollow self-resetting type, 50T ~ 100T ton hydraulic cylinder is manual reset type (electric pump can be equipped), the numerical display part of this instrument is The integrated multi-function display instrument adopts the sensor imported from Switzerland with high sensitivity and accurate value. It can directly read the tension value (kN) and has automatic calculation, peak hold, storage and query functions. It has a backlight display and a hollow hydraulic cylinder with a dust-proof system. And imported sealing ring, long service life, especially suitable for laboratory and field use, easy to operate, easy to learn and use.
Features
1. The digital display meter adopts sensors imported from Switzerland, and the measurement accuracy is 1% FS
2. 500 pieces of data recording, query, LCD lighting functions;
3. Peak hold, no operation automatic shutdown;
4. Numerical 10-segment broken line correction to improve the accuracy of the instrument;
5. The power supply method is a 2000mAh large-capacity rechargeable battery, and the continuous working time can exceed 200 hours
6. Imported sealing ring, durable, automatic spring reset, simple structure
7. Corrosion-resistant electrostatic spraying on the surface of the hydraulic cylinder, nickel-plated piston and sliding sleeve
8. The hollow part is equipped with a dust cover, overload protection, and quick oil-leakage joints
Specifications
| Product number | KS-10T | KS-20T | KS-30T | KS-50T | KS-60T | KS-100T |
| Measuring range | 0-100KN | 0-200KN | 0-300KN | 0-500KN | 0-600KN | 0-1000KN |
| Cylinder center hole | 27mm | 34mm | 45mm | 60mm | 75mm | 86/95mm |
| Cylinder stroke | 60mm | 80mm | 80mm | 120mm | 120mm | 150mm |
| Cylinder weight | 5.5kg | 13kg | 15kg | 25kg | 35kg | 50/75kg |
| Cylinder reset | Automatic reset | manual reset | ||||
| Hand pump oil storage capacity | 0.7L | 4L | ||||
| Manual pump working pressure | 63Mpa | |||||
| Instrument resolution | 0.01KN | 0.1KN | ||||
| Test accuracy | 1%FS | |||||
| Power supply | 2000mAh high capacity rechargeable battery | |||||
| display size | 55mmX21mm | |||||
| data storage | 500 | |||||



KOSON KS-50T Anchor pullerSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0~500KN |
| Cylinder center hole | 60mm |
| Cylinder stroke | 120mm |
| Cylinder Weight | 25kg |
| Cylinder reset | Manual reset |
| Manual pump oil storage | 4L |
| Working pressure | 63Mpa |
| Instrument Resolution | 0.01KN |
| Test Accuracy | 1%F.S |
| Power Supply | 2000mAh high Capacity rechargeable battery |
| Display size | 55*21mm |
| data storage | 500 articles |
| Standards | GB50367-2006、GB50330-201、JGJ120-2012、CECS22:2005、GB50007-2011、CECS22:99JGJ145-2013 |
KOSON KS-50T Anchor puller Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to determine film Adhesion by cross-cutting method?
- [Film Properties and Measurements] - Determination of paint film adhesion
- Systematic Understanding of Bolt Drawing Instrument: Structure, Principle & Operation and Maintenance
- Detailed Explanation of Coating Adhesion Determination Method
- Detailed explanation of performance detection method of coating Adhesion