TQC SP1831 Conical Mandrel Tester, Basic
The Dutch TQC SP1831 Conical Mandrel Tester is a basic version of the Conical Mandrel Tester. The P1831 is used to bend coating test plates on conical mandrel to evaluate the resilience or resistance of the coating. Its advanced model is SP1830.
TQC sheen-
PUSHEN WZJ-II T-Bend folding machine, film bending performance test
$ 753.00 -
CHINA NBC-7128 finished shoe bending testing machine
$ 1944.00 -
QTZ film cone bending test YONGLIDA film coating cracking performance test
$ 229.00 -
TQC SP1830 Conical Mandrel Tester Pro
$ 2773.00 -
MODERNER ZW-I Conical Mandrel Bending Tester - Elongation test of adhesive coatings for paints, varnishes, etc
Login
The TQC Cone Flexure Test "Basic" is a simplified version of the TQC Cone Flexure Test "Pro" (SP1830). It is a laboratory piece of equipment used to bend a coated test plate on a conical mandrel to assess the elasticity or resistance of the coating – from a metal test plate to paint or varnish for cracking, elongation, and/or separation according to ISO 6860 and ASTM D522. The tapered shape of the bending area allows for the deformation of the test plate and the elastic range of the coating to be checked in a single test on any diameter between 3.1 and 38mm. The plate is held in place by two clamping knobs, which need to be tightened and loosened by turning clockwise or counterclockwise.
The rugged device is made of a combination of anodized aluminum and stainless steel. Large knobs on the bending arm for easy bending.

Application
Automotive, Coating Industry, Laboratory, Coatings
Meet the criteria
Standards: ASTM D522, ISO 6860
TQC sheen SP1831 Conical Mandrel TesterSpecifications
| LIST | VALUE |
|---|---|
| Taper shaft size | Φ3.1~38mm |
| Measurement board size | 100*180mm |
| plate thickness | ≤0.8mm |
| Device size | 110*270*100mm |
| Weight | 3300g |
| meet the standard | ASTM D522, ISO 6860 |
TQC sheen SP1831 Conical Mandrel Tester Packing list
Host × 1, product manual × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Analysis of Conical Mandrel Test of ASTM D522 Film
- Detailed explanation of 3 methods for measuring film flexibility
- ActiveNF
- ActiveHG/T 5173-2017
- ActiveSH/T 3022-2019
- ActiveASTM
- ActiveDIN EN ISO 6860-2006
- ActiveNF EN ISO 6860-2007
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveSY/T 4106-2016
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012
- ActiveDB 44/T 1024-2012
- ActiveHG/T 5368-2018
- ActiveHG/T 4568-2013
- ActiveHG/T 4770-2014


SP1831
SP1830




