Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Rotational Viscometer> NiRun> NiRun HPDV-1 Portable Digital Viscometer
      NiRun HPDV-1 Portable Digital Viscometer

      NIRUN HPDV-1 Portable Digital Viscometer Measurement range 200~1.2 million mPa · s

      Measurement range 200~1200000mPa · s, rotor specifications B1, B2, B3, B4 four kinds of rotors, Rotor speed 60/100/150/200rpm, reproducibility +/- 1% F.S, Measurement accuracy +/- 2% F.S.

      Brand
      SKU: NB008743
      China NiRun
      Model
      Stock
      Loading…
      Price
      $ 1224.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • NiRun HPDV-1 Portable Digital ViscometerOverview

        • Specifications
        • Comments
        • FAQs
        HPDV-1
        Portable Digital Viscometer
        • NIRUN HPDV-1 Portable Digital Viscometer Measurement range 200~1.2 million mPa · s
        Measurement range 200~1200000mPa · s, rotor specifications B1, B2, B3, B4 four kinds of rotors, Rotor speed 60/100/150/200rpm, reproducibility +/- 1% F.S, Measurement accuracy +/- 2% F.S.

        technical features

        ◆Microcomputer control technology, user-friendly interface;

        ◆New humanized design, simple operation, accurate and fast measurement;

        ◆It has full scale and linearity measurement correction for each block;

        ◆New design, LCD display,

        Non-slip handle design, over-range alarm;

        ◆The screen directly displays temperature, viscosity, speed, percentage torque, rotor number and the maximum viscosity value of the selected rotor that can be measured at the current speed;

        ◆Unique structural design to ensure service life and measurement accuracy;

        ◆Ac and dc power supply dual-purpose design, lithium battery power supply for continuous measurement for 8 hours without charging;

        ◆Portable package, can be used in the field, laboratory and factory assembly line, on-site fluid viscosity measurement.

        application

        HPDV-1 Portable Digital Viscometer is suitable for ink, glue , latex , solvent-based adhesives , polymer solutions , petroleum , paint coatings , solvents , cosmetics , milk products , medicines , juices, etc.

        Three different application methods

        Portable viscometer in three different ways


        Pictures

        NIRUN HPDV-1 Portable Digital Viscometer Display

        VS

        NiRun HPDV-1 Portable Digital ViscometerSpecifications

        LIST VALUE
        Display digital display
        Measuring range 200~1200000mPa·s
        Rotor Specifications B1, B2, B3, B4 4 kinds of rotors
        Rotor speed 60/100/150/200rpm
        Reproducibility ±1%F.S
        Measurement Accuracy ±2%
        Power AC100-240V,50Hz/60Hz,DC17V1.2A
        Weight 7kg
        Encasement material Five-layer cardboard
        Collection method continuous acquisition
        Capacity 300~600ml
        Capacity 400 or 800ml (self-provided)
        Lifting system Metal lifting system
        Bearing system ruby
        Torque material beryllium bronze
        Control system microcomputer
        software system Data collection, programming, analysis
        temperature probe PT100 temperature probe
        Encasement aluminum alloy

        NiRun HPDV-1 Portable Digital Viscometer Packing list

        host x1, rotor x4, manual x1, warranty card x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        We need the paste in this slurry that can measure the viscosity of the slurry, which is the slurry of the small crispy meat. Viscosity range Approximately 3000 mPa
        [A]
        This one can be tested.
        [Q]
        Is this rotational viscometer rechargeable?
        [A]
        No, it is a lithium battery, which can be continuously measured for 8 hours. It can also be directly connected to the power supply.
        [Q]
        You can pull out the direct test after stirring, but because it needs to be adjusted, no sampling is required. Viscometer recommends direct testing?
        [A]
        This one is ok.
        [Q]
        Can the NIRUN HPVD-1 Portable Digital Viscometer meet the SN/T2903 standard?
        [A]
        Applicable, please consult the customer service of the mall for details about the SN/T2903 standard.
        [Q]
        Does the HPDV-1 Digital Viscometer have any requirements for the sample size to be tested?
        [A]
        Hello, it is generally 300~ 600ml.
        +NiRun HPDV-1 Portable Digital Viscometer Big data
          +NiRun HPDV-1 Portable Digital ViscometerSimilar products
          +NiRun HPDV-1 Portable Digital ViscometerKnowledge
          +NiRun HPDV-1 Portable Digital ViscometerStandard
          +Navigation
          NiRun
          NIRUN HPDV-1 Portable Digital Viscometer Measurement range 200~1.2 million mPa · s
          Service
          Focus on online sales of Lab Testing Instruments