NIRUN SNB-3 Digital Viscometer Measurement range 100~80 million mPa · s
Digital display, Measurement range 100~80000000mPa · s, Rotor specifications 1 #, 2 #, 3 #, 4 #, Rotor speed 0.1~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
NiRun-
FANGRUI SNB-1T Digital Rotational Viscometer Viscosity: 1~ 2 million mPa·s
$ 593.00 -
Fungilab V-pad L Rotational Viscometer 6 million cP
$ 7657.00 -
NIRUN 1000 series, standard solution (not sold separately)
$ 192.00 -
FANGRUI LV-SSR-H Viscometer Coaxial Cylinder Structure, Small Sample Adapter
$ 1470.00 -
FANGRUI NDJ-8S Digital Rotational Viscometer with ULR Ultra Low Viscosity Adapter
$ 593.00
Features
It can be used as a stand-alone machine or connected to a micro printer and computer for data collection.
The stepper motor rotates with high subdivision drive, the speed is accurate and stable, and the change of AC Voltage frequency does not affect the accuracy of measuring viscosity.
For thixotropic non-Newtonian liquids, the timing function of the viscometer ensures good consistent data.
The LCD has a blue backlight function, which directly displays the viscosity, rotational speed, percentmeter torque, the maximum viscosity value and temperature value that can be measured by the rotor at the current speed. The viscosity value shows a continuous variation. When the measurement range is out, there is an alarm sound.
SNB data acquisition and plotting software can be purchased for data acquisition and data analysis, and micro monochrome printers can also be purchased for timed printing of measurement results.
The full-scale range and linearity of the instrument are all calibrated through the computer interface, and its measurement performance and function have reached the same professional level abroad.
RTD temperature probe is standard to monitor the sample temperature in real time with an accuracy of 0.1°C and a temperature range of 0-100°C.
It adopts 16-bit microcomputer processor as the core, high-subdivision drive stepper motor, and digital LCD with blue backlight function.
Depending on your needs, you can choose a different standard rotor.
According to the need, the reference materials of the Bureau of Metrology can be purchased to calibrate the viscometer, so that the inspection level is in line with the international standard.
SNB data acquisition and plotting software is optional
Product Applications
SNB-3 digital viscometer is widely usedInks, glues、latex、Solvent-based adhesives、Polymer solution、petroleum、Paints and coatings、solvent、cosmetics、Milk products、*product、juices and much more.
Product display diagram

Optional
Ultra-low viscosity adapter (rotor size 0)
Micro printers
Dedicated viscosity thermostatic sink
SNB data acquisition and mapping software
Small sample adapter (with 21#, 27#, 28#, 29# rotors)
Standard oil
Remote control.
Comparison of SNB parameters
| Model | Measuring range | Rotor speed | Measurement method |
| SNB-1 | 1-600,000 | 1-60 | Manual |
| SNB-2 | 1-6 million | 0.1-100 | |
| SNB-3 | 4-80 million | 0.1-100 | |
| SNB-AI | 1-6 million, 4-80 million | 0.1-200 | Manual, intelligent |
| Unit: mPa·s, revolutions/minute | |||
| Other parameters | |||
| Number of rotors | 4 rotors of 1, 2, 3 and 4 (rotor 0 is optional) | ||
| Measurement accuracy | ±1.0% (full scale) | ||
| repeatability | 0.50% | ||
NiRun SNB-3 Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Measurement range | 100~80000000mPa·s |
| Rotor specification | 1#、2#、3#、4# |
| Rotor speed | 0.1~100rpm |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | AC100-240V,50Hz/60Hz,DC17V1.2A |
| Weight | 7kg |
| collection method | continuous acquisition |
| Encasement material | Five-layer cardboard |
| Capacity | 300~400ml |
| Capacity | 400Ml (self-prepared) |
| Lifting system | PE lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, mapping |
| temperature sensor | RID temperature sensor |
| Encasement | aluminum alloy |
| Rotation speed Control mode | Continuously variable speed |
NiRun SNB-3 Digital Viscometer Packing list
Host x1, one rotor each for 1 #, 2 #, 3 #, and 4 #, manual x1, warranty card x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Coating rheology is determined
- National Standard for Coating Viscosity Determination [Rotational Viscometer method]
- what is Viscometer?
- Coating Viscosity Determination Method (Daquan Explanation)
- Nerun teaches you how to properly maintain an online Viscometer?
- Pressure sensitive adhesive Viscosity test and test instrument introduction
- How to properly use Flow Cup to measure Coating Viscosity?


SNB-3