NIRUN LDV-2 + Pro Digital Viscometer Measurement range 10~6 million cP
Digital display, Measurement range 10~6000000mPa · s, Rotor specifications 1 #, 2 #, 3 #, 4 #(0 #optional), Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage 110~220V 50Hz/60Hz.
NiRun-
HUINUO NDJ-5S Digital Rotational Viscometer with RTD temperature sensor
$ 466.00 -
HUINUO SNB-RH high temperature Rotational Viscometer asphalt hot-melt adhesive Viscometer
$ 1656.00 -
HUINUO NDJ-8S Digital Rotational Viscometer with a small number of sample adapters
$ 910.00 -
CNSHP SNB-1 Digital Rotational Viscometer viscosity up to 100000mPa.s
$ 501.00 -
NIRUN NTV-S1 Smart Touch Digital Viscometer Measurement range 1-600,000 mPa.s
$ 1774.00
Technical advantages
It can be used as a stand-alone machine, or it can be connected to a micro-printer and a computer to realize data collection.
High subdivision drives the stepper motor to rotate, the speed is accurate and stable, and the frequency change of AC Voltage does not affect the accuracy of viscosity measurement.
For thixotropic non-Newtonian liquids, the timing function of the instrument can ensure good consistency data.
With humanized, personalized design, 2000 kinds of shear rate stepless setting. It can simultaneously display shear stress, shear rate, rotational speed, viscosity, time, temperature and the maximum viscosity value that the rotor can measure at the current rotational speed.
DVLoad software can be purchased to download the custom measurement program to the instrument to realize full computer automatic operation, and DV data acquisition and program-controlled analysis software can also be purchased to realize data acquisition and program-controlled analysis.
The full scale and linearity of LDV-2+Pro digital viscometer are all measured and corrected through the PC interface, and its measurement performance and functions have reached the professional level of the same type abroad.
The built-in RTD temperature probe monitors the sample temperature in real time, with an accuracy of 0.1°C and a temperature range of 0-100°C.
Different standard rotors can be selected according to needs
Using 16-bit microcomputer processor as the core stepping motor high subdivision drive, digital LCD with blue backlight function.
According to the need, you can choose the standard material of the Metrology Bureau to calibrate the viscometer, so that the inspection level can be in line with the international standard.
plan

optional accessories
Small sample adapter (with 21#, 27#, 28#, 29# rotor
If a small sample adapter is selected, the measuring range will be reduced by 6 times under the corresponding specification)
Ultra Low Viscosity Adapter (Spindle 0)
micro printer
Special viscosity constant temperature Water Tank
DV data acquisition and program control analysis software
standard oil
Comparison of DV parameters
| model | Measuring range (mPa.s) | Rotor speed | |||
| LDV | RDV | HADV | HBDV | ||
| DV-1+PRO | 1-2 million | 1-13 million | 2-26 million | 8-104 million | 0.3-100 |
| DV-2+PRO | 1-6 million | 100-40 million | 2-80 million | 800-320 million | 0.1-200 |
| DV-3+PRO | 1-6 million | 20-40 million | 100-80 million | 5-320 million | 0.1-250 |
| DV-E | 1-2 million | 1-13 million | 2-26 million | 8-104 million | 0.3-100 |
| Unit: mPa.s, rev/min | |||||
| Other parameters | |||||
| Number of rotors | LDV with (1, 2, 3, 4 4 kinds of rotors) (0 rotor is optional) | ||||
| RDV, HADV, HBDV (6 types of rotors No. 2, 3, 4, 5, 6, 7) (Rotors No. 0 and No. 1 are optional accessories) | |||||
| measurement accuracy | ±1.0% (full scale) | ||||
| repeatability | 0.50% | ||||
NiRun LDV-2+Pro Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 10~6000000mPa·s |
| Rotor Specifications | 1 #, 2 #, 3 #, 4 #(0 #optional) |
| Rotor speed | 0.1~200rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | 110~220V 50Hz/60Hz,DC17V1.2A |
| Data Interface | RS232 |
| Weight | 7kg |
| Capacity | 600Ml beaker or optional small sample adapter |
| Encasement material | Five-layer cardboard |
| Collection method | continuous acquisition |
| Capacity | 300~600ml |
| Capacity | 400 or 800ml (self-provided) |
| Lifting system | Metal lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, programming, analysis |
| temperature probe | PT100 temperature probe |
| Encasement | aluminum alloy |
| Speed control method | Continuously variable speed (no gear drive) |
NiRun LDV-2+Pro Digital Viscometer Packing list
host x1, rotor x4, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Determination of starch viscosity by swirl/spin Viscosity meter
- Determination Principle and Detection Method of Coating Viscosity
- 5 points to note when using online Viscometers
- Printing ink viscosity inspection method
- How to properly use Flow Cup to measure Coating Viscosity?
- Difference and comparison of three series of NDJ/SNB/DV rotary viscometer
- Coating Printing ink Viscosity performance testing instrument type summation
- ActiveHG/T 4443-2012
- ActiveEN 16896-2016
- ActiveHG/T 3323-2008
- ActiveGB/T 24148.4-2009
- ActiveGB/T 21059-2007
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- AbolishGB/T 11175-2002
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveFZ/T 10020-2011


LDV-2+Pro
HBDV-2+Pro
RDV-2+Pro