NIRUN HADV-2 + Pro Digital Viscometer Measurement range 40-80 million cP
Digital display, Measurement range 40~80000000mPa · s, Rotor specifications 2 #, 3 #, 4 #, 5 #, 6 #, 7 #(1 #optional), Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Control system Microcomputer, software system data collection, programming, analysis, temperature sensor PT100 temperature sensor, Encasement aluminum alloy, Rotation speed Control mode continuously variable speed (no gear drive).
NiRun-
TQC DV2204 viscosity calibrated oil S60 500ml
$ 428.00 -
SDPTOP NDJ-1 Pointer Viscometer measurement range: 1~ 100000mPa · s
$ 428.00 -
HUINUO SNB-3 solder paste digital Rotational Viscometer 80 million cp with printer
$ 1345.00 -
Shangtian Jingyi NDJ-8S Digital Viscometer NDJ Rotational Viscometer 2X10 mPa · s
$ 742.00 -
NIRUN NDJ-8S + Ultra Low Viscosity Adapter, New Digital Viscometer
$ 1137.00
Features
Optional DV data acquisition and programmable software measures rheological properties
Displays the shear rate and shear stress
The stepper motor is directly driven, gearless and the speed is accurate
The LCD LCD has a blue backlight and displays a large amount of information
The maximum viscosity value that can be measured by the rotor at the current speed is displayed.
The viscosity value shows a continuous variation
When the measurement range is out, there is an alarm sound
An RTD temperature probe is standard
Bidirectional RS232 or 485 interface as standard
Computerized full-scale linear correction
AC power adapter 100V-240V, good anti-interference
Application
HADV-2+Pro digital viscometer is widely usedInks, glues、latex、Solvent-based adhesives、Polymer solution、petroleum、Paints and coatings、solvent、cosmetics、Milk products、*product、juices and much more.
Product display diagram

Optional
DV data acquisition and program-controlled analysis software
Dedicated viscosity measurement thermostatic sink
Ultra-low viscosity adapters
Small sample adapters
Standard solutions
Micro printers
Externally recirculating glass beaker
Comparison of DV parameters
| Model | Measuring range (mPa.s) | Rotor speed | |||
| LDV | RDV | HADV | HBDV | ||
| DV-1+PRO | 1-2 million | 100-13 million | 200-26 million | 800-104000000 | 0.3-100 |
| DV-2+PRO | 1-6 million | 100-40 million | 200-80 million | 800-320000 | 0.1-200 |
| DV-3+PRO | 1-6 million | 20-40 million | 100-80 million | 500-320000 | 0.1-250 |
| DV-E | 1-2 million | 100-13 million | 200-26 million | 800-104000000 | 0.3-100 |
| Unit: mPa.s, revolutions per minute | |||||
| Other parameters | |||||
| Number of rotors | LDV (4 rotors 1, 2, 3, and 4) (rotor 0 is optional) | ||||
| RDV, HADV, HBDV (6 rotors 2, 3, 4, 5, 6, 7) (0, 1 rotors are optional) | |||||
| Measurement accuracy | ±1.0% (full scale) | ||||
| repeatability | 0.50% | ||||
NiRun HADV-2+Pro Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Measurement range | 40~80000000mPa·s |
| Rotor specification | 2 #, 3 #, 4 #, 5 #, 6 #, 7 #(1 #optional) |
| Rotor speed | 0.1~200rpm |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | AC100-240V,50Hz/60Hz,DC17V1.2A |
| Interface | RS232 |
| Weight | 7kg |
| Capacity | 600Ml beaker or optional small sample adapter |
| Encasement material | Five-layer cardboard |
| collection method | continuous acquisition |
| Capacity | 300~600ml |
| Capacity | 400 or 800ml (self-matching) |
| Lifting system | Metal lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, programming, analysis |
| temperature sensor | PT100 temperature sensor |
| Encasement | aluminum alloy |
| Rotation speed Control mode | Continuously variable speed (without gear drive) |
NiRun HADV-2+Pro Digital Viscometer Packing list
host x1, rotor x6, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Operation steps and precautions for the use of Nirun viscometer
- How to Tell if a Digital Viscometer is Accurate
- How to measure unknown viscosity samples
- 455N digital Rotational Viscometer operating instructions
- Viscometer selection: How to choose NDJ/SNB/LV/RV/HA/HB Rotational Viscometer?
- Nerun: Correction of Digital Viscometers
- 5 points to note when using online Viscometers
- ActiveGB/T 12009.3-2009
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveFZ/T 10020-2011
- ActiveJIS K5101-6-2-2004
- AbolishGB/T 2794-2013
- AbolishGB/T 2794-1995
- ISO 2884-2-2003
- ActiveJB/T 9357-1999
- ActiveGB/T 22235-2008
- ActiveGB/T 10247-2008


HADV-2+Pro
HBDV-2+Pro
RDV-2+Pro
HADV-2+Pro
LDV-2+Pro