FANGRUI instrument SNB-1A Digital Rotational Viscometer viscosity range 10~200,000 cp
The FANGRUI instrument SNB-1A Digital Rotational Viscometer is a relatively simple Rotational Viscometer of the SNB series, providing four rotor options. The sample dosage of the SNB-1A Digital Rotational Viscometer is 15~ 25ml.
-
TQC DV2201 Viscosity calibrated oil N10 500ml
$ 428.00 -
HUINUO NDJ-5S Digital Rotational Viscometer with RTD temperature sensor
$ 466.00 -
Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
$ 2092.00 -
NIRUN NTV-P1HB Programmable Digital Viscometer swirl/spin Viscometer 800~104M mPa.s
$ 3289.00 -
NIRUN SNB-2 Digital Rotational Viscometer Measurement range 10~6 million mPa · s
$ 1462.00
Introduction
Fangrui Instrument SNB-1A digital display Rotational Viscometer adopts the new international microcomputer drive technology, imported stepper motor, LCD backlight display, program setting, automatic control, with stable speed, good accuracy, easy operation, error alarm and other practical functions; Information such as viscosity, rotational speed, rotor number, percent specific torque, and the temperature of the liquid to be measured is displayed directly on the screen. The instrument is all measured and corrected by standard silicone oil for the full scale and linearity of each block through the PC interface to ensure that the instrument has high sensitivity, high precision and high repeatability. The measured data is accurate, reliable and reproducible.
Features
(1) The viscosity value of the tested sample is directly displayed on the LCD screen, without manual calculation;
(2) Adopt the new international microcomputer drive technology, imported synchronous feed motor, LCD backlight display;
(3) Adopt professional switching power supply design, wide working power supply range, and the fluctuation of mains power does not affect the measurement accuracy;
(4) The whole machine is designed to be easy to operate;
(5) SNB-1A special sample adapter for small dose samples. Unlike the commonly used 1~4# rotor that requires a sample volume of 200~400ml, the sample adapter only needs a sample volume of 20ml.
⑥ The digital viscometer adopts a small screen English backlight liquid crystal display;
⑦ The instrument can provide a low-viscosity test option "No. 0 rotor" to accurately test the viscosity value in the range of 0.1~100MPa.s;
⑧ The temperature probe can be selected to measure the temperature of the tested sample in real time, and the temperature measurement accuracy is 0.1°C;
⑨ There is RS232 interface (or optional USB2.0 interface), which can output data and connect external devices;
In addition, data processing software is standard, which can record the change of sample viscosity with time, rotational speed or rotor (shear rate) and temperature in real time, which provides a good analytical method for understanding the viscosity and rheological properties of non-Newtonian liquids.
Applications
It is widely used in the production of oils, paints, coatings, slurries, textiles, foods, adhesives, cosmetics and other fluids and semi-fluids in scientific research units. With the advantages of accurate, fast, intuitive and simple measurement, the instrument has been selected by customers in various industries.
Product display diagram

FangRui SNB-1A Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | Small LCD display |
| Measurement range | 10~200000mPa·s |
| Rotor specification | 21#、 27#、28#、29# |
| Rotor speed | 0.5/1/2/5/10/20/50rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | 110~230V 50Hz/60Hz |
| Interface | R232C Communication interface one, temperature sensor interface one, power jack one |
| Dimensions | 300*300*450mm |
| Weight | 5kg |
| Capacity | 15~25ml |
FangRui SNB-1A Digital Viscometer Packing list
Viscometer host x1, rotor x1 (21 #, 27 #, 28 #, 29 #sets), triangular base x1, column x1, sample container cup x1, power adapter x1, instrument aluminum box gold foil x1, sample cylinder x1, rotor protection frame x1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Coating rheology is determined
- National Standard for Coating Viscosity Determination [Rotational Viscometer method]
- what is Viscometer?
- Working principle and application scenario analysis of NDJ digital Rotational Viscometer
- Coating Viscosity Determination Method (Daquan Explanation)
- Determination of Coating Viscosity
- Viscosity performance of gravure Printing ink
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveHG/T 3660-1999
- ActiveGB/T 15357-2014
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveFZ/T 10020-2011
- ActiveJIS K5101-6-2-2004
- AbolishGB/T 2794-2013
- AbolishGB/T 2794-1995
- ActiveGB/T 265-1988
- ISO 2884-2-2003
- ActiveGB/T 5561-2012
- ActiveJB/T 9357-1999


FangRui
SNB-1A
RV-SSR