NIRUN SNB-AI + 500 degree heater, digital Viscometer 500 ℃
NIRUN SNB-AI + 500 Degree Heater Digital Viscometer is equipped with a heater that can heat up to 500 ℃. The Viscosity range of SNB-AI Digital Viscometer is 5~ 1 million mpa · s.
NiRun-
NIRUN LDV-3 + Pro Digital Viscometer Viscosity Range 10 to 6 million cP
$ 3938.00 -
MODERNER NDJ-5T Rotational Viscometer 1~ 100,000 mPa · s viscosity range
Login -
NIRUN 50 series, standard solution (not sold separately)
$ 145.00 -
NIRUN NTV-S2 Smart Touch Digital Viscometer Measurement range 1-6 million mPa.s
$ 2037.00 -
NIRUN 3000 series, standard solution (not sold separately)
$ 192.00
technical features
Intelligent measurement. Automatically adjust the speed to reduce the difficulty of use for beginners.
Small amount of sample
The sample chamber is insulated to reduce the heat loss of the sample
Temperature control with little fluctuation
The rotor rotates and plays the role of stirring
Optional SNB data acquisition software to record the viscosity-temperature curve throughout the process
Easy temperature control
Applications
SNB-AI digital viscometer is widely used in hot melt adhesive, asphalt, paraffin, high polymer .
Pictures

optional accessories
SNB Data Acquisition and Graphing Software
NiRun SNB-AI + 500 degree heater Digital ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 5~1000000mPa·s |
| Rotor Specifications | 21#、 27#、28#、29# |
| Rotor speed | 0.1~200rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | AC100-240V,50Hz/60Hz,DC17V1.2A |
| Weight | 7kg |
| Furnace body temperature range | Room temperature~ 500 ℃ |
| Encasement material | Five-layer cardboard |
| Collection method | continuous acquisition |
| Capacity | 300~400ml |
| Capacity | 400Ml (self-prepared) |
| Lifting system | PE lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | Data collection, mapping |
| temperature probe | RID temperature probe |
| Encasement | aluminum alloy |
| Speed control method | CVT |
NiRun SNB-AI + 500 degree heater Digital Viscometer Packing list
Host x1, rotor x4, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Methods for Verifying the Accuracy of a Digital Viscometer
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Coating rheology is determined
- National Standard for Coating Viscosity Determination [Rotational Viscometer method]
- what is Viscometer?
- Coating Viscosity Determination Method (Daquan Explanation)
- How to recalibrate Nerun Digital Viscometer?
- How Digital Viscometers Work
- ActiveGB/T 8884-2017
- Active 0739-2014
- ActiveJC/T 2678-2022
- ActiveGB/T 22427.7-2023
- ActiveSN/T 0739-2003
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveGB/T 15357-2014
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveGB/T 14490-2008
- ActiveGB/T 5561-2012
- ActiveJB/T 9357-1999


SNB-AI + 500 degree heater





