NIRUN LDV-T1 Digital swirl/spin Viscosity meter Viscosity range 10~330000MPa · s
Digital display, Measurement range 10~330000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Control system: microcomputer, Software system: DV-T1 data collection and drawing software, Rotation speed Control mode stepless speed change.
NiRun-
HUINUO NDJ-4S digital display Rotational Viscometer 2 million CP
$ 505.00 -
FANGRUI SNB-1 Digital Viscometer with RTD Temperature Probe
$ 511.00 -
MODERNER NDJ-8S Digital Rotational Viscometer viscosity range is 1-2000000cp
Login -
NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
$ 4875.00 -
NIRUN HADV-2 + Pro Digital Viscometer Viscosity Range 40-80 million mPa · s
$ 3553.00
Introduction
Nirun LDV-T1 digital display Rotational Viscometer is an all-in-one viscosity temperature control machine, which integrates viscosity measurement and precise temperature control. Breakthrough in the existing market has a constant temperature Water Tank, viscosity measuring instrument, small sample adapter composed of split machine.
Features
1. The all-in-one viscosity measurement system is composed of a small sample adapter (SSR) cylindrical sample sleeve and SC4 rotor, which can accurately measure at a certain shear rate, and the sample dosage only needs to be 2 to 16m, and the cylindrical geometry of the SC4 rotor can provide very accurate viscosity measurement.
2. It is convenient to load and unload a small sample barrel, which brings convenience to the cleaning work.
3. The small sample barrel is closely connected with the temperature controller, which can accurately carry out the constant temperature of the sample.
4. The stirring action of the rotor, coupled with the small amount of sample, can reduce the unevenness of the sample temperature to a minimum. The constant temperature time is greatly reduced.
5. Controlling the temperature when measuring viscosity helps to ensure the accuracy of the experimental results, because the temperature controller is composed of semiconductors and built-in automatic optimization temperature program control, the temperature control accuracy is ±0.1°C.
6. The temperature control is operated by DV-T1 data acquisition and plot analysis software, which has good operation performance and flexibility.
Product display diagram

Comparison of DV-T viscometer series parameters
| Model | LDV-T1 | RDV-T1 | HADV-T1 | HBDV-T1 |
| Measuring range mPa·s | 5-330,000 | 50-3.3 million | 100-6.6 million | 400-26.4 million |
| Rotor speed | 0.1~100 rpm (continuously variable speed) | |||
| Number of rotors | Standard configuration SC4-21, 27, 28, 29 (optional rotor SC4-14, 15, 16, 18, 25, 31, 34) | |||
| Sample size | 2-16ml | |||
| Temperature range | -1°C-150°C (Temperature control accuracy±0.1°C) | |||
| repeatability | 0.5% F/S | |||
| Measurement accuracy | ±1.0 F/S | |||
NiRun LDV-T1 Digital ViscoMeterSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Measurement range | 10~330000mPa·s |
| Rotor specification | SC4-21, 27, 28, 29 |
| Rotor speed | 0.3~100rpm |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | AC100-240V,50Hz/60Hz,50Hz/60Hz |
| Encasement material | Five-layer cardboard |
| collection method | continuous acquisition |
| Capacity | 2~16ml |
| Lifting system | Metal lifting system |
| Bearing system | ruby |
| Torque material | beryllium bronze |
| Control system | microcomputer |
| software system | DV-T1 data collection and mapping software |
| Rotation speed Control mode | Continuously variable speed |
NiRun LDV-T1 Digital ViscoMeter Packing list
host x1, rotor x4, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Methods for Verifying the Accuracy of a Digital Viscometer
- Viscometer Determination Methods of Several Paints
- What is the rheology of paint, how to measure?
- Introduction to performance test of PC surface UV curing organic-inorganic hybrid hardening coatings
- Coating rheology is determined
- National Standard for Coating Viscosity Determination [Rotational Viscometer method]
- what is Viscometer?
- Coating Viscosity Determination Method (Daquan Explanation)
- Nerun: Correction of Digital Viscometers
- How to Prepare High Solids Polyester Resin?


LDV-T1