      NIRUN HBDV-T1 Digital Rotational Viscometer viscosity range 400~26400000MPa · s

      Digital display, Measurement range 400~26400000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Temperature range -1~ 150 ℃, Temperature accuracy +/- 0.1 ℃.

      Brand
      SKU: NB008858
      China NiRun
      Model
      VS
      Information
      Genuinegoods
      • NiRun HBDV-T1 Digital ViscometerOverview

      • Specifications
      • Comments
      • FAQs
      HBDV-T1
      Digital Viscometer
      • NIRUN HBDV-T1 Digital Rotational Viscometer viscosity range 400~26400000MPa · s
      Digital display, Measurement range 400~26400000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Temperature range -1~ 150 ℃, Temperature accuracy +/- 0.1 ℃.

      Introduction

      NIRUN HBDV-T1 digital display rotary viscometer is a viscosity temperature temperature control integrated machine, which integrates viscosity measurement and precise temperature control in one. It breaks through the existing market that has a constant temperature Water Tank, a viscosity measuring instrument, and a small amount of sample adapter to form a split machine.

      Features

      1. The all-in-one viscosity measurement system is composed of a small sample adapter (SSR) cylindrical sample sleeve and SC4 rotor, which can be accurately measured at a certain shear rate. The sample volume only needs 2 to 16m, and the SC4 rotor is cylindrical The geometry provides very accurate viscosity measurements.

      2. The small sample cylinder is easy to load and unload, which brings convenience to the cleaning work.

      3. The small-volume sample cylinder is closely connected with the temperature controller, which can accurately keep the temperature of the sample.

      4. The stirring action of the rotor, coupled with the small amount of sample, can minimize the inhomogeneity of the sample temperature. The constant temperature time is greatly shortened.

      5. Controlling the temperature when measuring the viscosity helps to ensure the accuracy of the experimental results. Since the temperature controller is composed of a semiconductor and a built-in automatic optimization temperature program control, the temperature control accuracy reaches ±0.1°C.

      6. The temperature control is operated by DV-T1 data acquisition and drawing analysis software, which has good operating performance and flexibility.

      Models

      modelViscosity range
      LDV-T15-330,000 mPa.s
      RDV-T150-33,000 mPa.s
      HADV-T1100-66,000 mPa.s
      HBDV-T1400-264,000 mPa.s

      Pictures

      NIRUN HBDV-T1 Digital Display Rotational Viscometer Display

      VS

      NiRun HBDV-T1 Digital ViscometerSpecifications

      LIST VALUE
      Display digital display
      Measuring range 400~26400000mPa·s
      Rotor Specifications SC4-21, 27, 28, 29
      Rotor speed 0.3~100rpm
      Reproducibility ±0.5%F.S
      Measurement Accuracy ±1%
      Power AC100-240V,50Hz/60Hz,DC17V1.2A
      Temperature range -1~150℃
      temperature Accuracy ±0.1℃
      Encasement material Five-layer cardboard
      Collection method continuous acquisition
      Capacity 2~16ml
      Lifting system Metal lifting system
      Bearing system ruby
      Torque material beryllium bronze
      Control system microcomputer
      software system DV-T1 data collection and plotting software
      Speed control method CVT

      NiRun HBDV-T1 Digital Viscometer Packing list

      host x1, rotor x4, manual x1, warranty card x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Which rotors can be used with this HBDV-T1 digital rotational viscometer?
      [A]
      Hello, the digital display rotational viscometer you mentioned can be used for SC4-21/27/28/29 (std.), SC4-14/15/16/18/25/31/34 #(optional) rotors.
      [Q]
      Can Shanghai Nirun HBDV-T1 be used for high viscosity sample testing?
      [A]
      Hello, HB or HA series are suitable for high viscosity sample testing, but the specific model requires some data of your system to accurately match the appropriate model.
      [Q]
      Can this NIRUN digital Viscometer correspond to GB/T22427.7?
      [A]
      Yes, please refer to the NBchao standards page for specific standards.