      NIRUN HADV-T2 Digital Viscometer Viscosity Range 50~20000000Mpa · s

      Digital display, Measurement range 50~20000000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Interface RS232, Temperature range - 1~ 150 ℃, Temperature accuracy +/- 0.1 ℃.

      Brand
      SKU: NB008861
      China NiRun
      Model
      VS
      Information
      Genuinegoods
      • NiRun HADV-T2 Digital ViscometerOverview

      • Specifications
      • Comments
      • FAQs
      HADV-T2
      Digital Viscometer
      • NIRUN HADV-T2 Digital Viscometer Viscosity Range 50~20000000Mpa · s
      Digital display, Measurement range 50~20000000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Interface RS232, Temperature range - 1~ 150 ℃, Temperature accuracy +/- 0.1 ℃.

      Introduction

      NIRUN HADV-T2 digital display viscometer is a viscosity temperature control integrated machine, which integrates viscosity measurement and precise temperature control in one. It breaks through the existing market that has a constant temperature Water Tank, a viscosity measuring instrument, and a small amount of sample adapter to form a split machine. The all-in-one viscosity measurement system is composed of a small sample adapter (SSR) cylindrical sample sleeve and SC4 rotor, which can perform accurate measurement at a certain shear rate. The sample volume only needs 2 to 16m, and the SC4 rotor has a cylindrical geometry. Can provide very accurate viscosity measurement, and can get accurate shear rate data. The small sample cylinder is easy to load and unload, which brings convenience to the cleaning work. The small-volume sample cylinder is closely connected with the temperature controller, so that the temperature of the sample can be kept very accurately. The stirring action of the rotor, combined with the small sample volume, minimizes sample temperature non-uniformity. The constant temperature time is greatly shortened.

      Precise temperature control is very helpful for testing the performance changes of your samples and predicting the behavior of products. Controlling the temperature when measuring the viscosity helps to ensure the accuracy of the experimental results. Since the temperature controller is composed of a semiconductor and a built-in automatic optimization temperature program control, the temperature rise/fall is adjustable, and the temperature control accuracy is ±0.1. Temperature control is operated by DV-T2 data acquisition and program-controlled analysis software, which has good operational performance and flexibility. DV-T2 data acquisition and program-controlled analysis software can do rheological curve analysis.

      Product Structure

      NIRUN HADV-T2 digital display viscometer front structure diagram

      NIRUN HADV-T2 digital display viscometer back structure diagram

      NIRUN HADV-T2 digital display viscometer connecting rod structure diagram

      Pictures

      NIRUN HADV-T2 digital display viscometer display

      Comparison of DV-T2 Viscometer Series Parameters

      modelLDV-T2RDV-T2HADV-T2HBDV-T2
      Range mPa·s5-1 million25-10 million50-20 million2-80 million
      Rotor speed0.1~200 rpm (continuously variable speed)
      Number of rotorsStandard configuration SC4-21, 27, 28, 29 (optional rotor SC4-14, 15, 16, 18, 25, 31, 34)
      sample size2-16ml
      temperature range-1°C-150°C (temperature control accuracy ±0.1°C)
      repeatability0.5% F/S
      measurement accuracy±1.0 F/S
      VS

      NiRun HADV-T2 Digital ViscometerSpecifications

      LIST VALUE
      Display digital display
      Measuring range 50~20000000mPa·s
      Rotor Specifications SC4-21, 27, 28, 29
      Rotor speed 0.1~200rpm
      Reproducibility ±0.5%F.S
      Measurement Accuracy ±1%
      Power AC100-240V,50Hz/60Hz,DC17V1.2A
      Data Interface RS232
      Temperature range -1~150℃
      temperature Accuracy ±0.1℃
      Encasement material Five-layer cardboard
      Collection method continuous acquisition
      Capacity 2~16ml
      Lifting system Metal lifting system
      Bearing system ruby
      Torque material beryllium bronze
      Control system microcomputer
      software system DV-T2 data collection and programmable analysis software
      Speed control method CVT

      NiRun HADV-T2 Digital Viscometer Packing list

      host x1, rotor x4, manual x1, warranty card x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Can the NIRUN HADV-T2 Digital Viscometer meet the GB/T18856.4 standard?
      [A]
      Applicable, you can consult the customer service of the mall for details about the GB/T18856.4 standard.
      [Q]
      Epoxy resin Coating viscosity measurement with what material Viscometer is better?
      [A]
      Measurement Coating viscosity generally can choose viscosity cup or Viscometer, viscosity cup mainly measures relative viscosity, Viscometer measures dynamic viscosity. In general, in addition to thixotropic Coating, Coatings under 150s can be coated with 4 cups, and Coatings under 20 can be coated with 1 cup. In addition, Yehui uses ISO flow cup to measure Newton-type liquid Coating viscosity, Stormer Viscometer to measure architectural coatings viscosity, and for all brush coatings, rotational viscometer or Cone and Plate Viscometer measurement can be used.
      NiRun
      NIRUN HADV-T2 Digital Viscometer Viscosity Range 50~20000000Mpa · s
      Service