EYESKY ES10B11-CH2O Fixed Formaldehyde Detector detection concentration 0~10ppm
The test concentration of ES10B11-CH2O fixed Formaldehyde Detector is 0~10ppm, and the resolution is 0.01ppm. The ES10B11-CH2O formaldehyde concentration Measurement Instrument has an instrument panel and an acousto-optic alarm.
EYESKY-
Empaer AATL-CH4 (Sound and Light Alarm) Pathfinder Series Fixed Methane Detector
$ 290.00 -
HUIRUIPU HRP-B1000-O2 Oxygen Gas Detector 0-30% VOL/0.1% VOL
$ 153.00 -
KORNO MOT500-CH2O-Y Online Formaldehyde Detector 0-10ppm
$ 434.00 -
BOSEAN BH-90M-PH3 phosphating hydrogen Gas Detector
$ 239.00 -
HUIRUIPU HRP-T1000-CO Carbon Monoxide Gas Detector (No display with light)
$ 156.00
Description
Visionless ES10B11-CH2O fixed formaldehyde Detector is a new one created by Visionless Technology on the basis of ES10AGas Detector, using original imported sensors and new ones32-bit low-power processor; Dashboard display boundarysurface, the value and the progress bar are displayed at the same time, which is beautiful and generous; Circuit adoption4 layers of wiring, against weak signals and anti-dryingDisturbance is stronger; Independent high-precision imports16-bit AD chip and signal processing algorithm to measure data accuracyHigher and more stable;4~20mA, RS485, 200~1000HZ a variety of output signals can be selected, easy to accessAlarm controllers, PLC, DCS and other control systems; Explosion-proof structures are designed to be used in a variety of hazardous industriesLocation; The products are widely used in metallurgy, petroleum and petrochemical, municipal, chemical and other industries.









Features
◆ Original imported high-performance sensor, long service life;
◆ Independent 16-bit AD chip, 4-layer circuit board design, stronger ability to weak signal and anti-interference;
◆ The dashboard display interface is designed, the reading is beautiful and generous, and the humanized detail design is reflected;
◆ White, orange and red backlight design, normal and alarm status indication, clear at a glance;
◆ mg/m3, ppm, VOL, LEL can be selected;
◆ Embedded 32-bit ultra-low power processor, with independent signal processing algorithm, fast response, high measurement accuracy, good stability and repeatability;
◆ Automatic protection function against high-concentration gas impact, with factory reset to prevent misoperation;
◆ The instrument is equipped with infrared remote control, which can be operated by remote control, without opening the cover, which is simple and convenient;
◆ Three-wire 4~20mA, RS485, 200~1000HZ signal output optional, relay output, data recovery, data storage and other functions;
◆ Two cable inlets, convenient for on-site installation;
◆ Independent air chamber structure, easy sensor replacement, no need for on-site calibration;
◆ Very good mechanical design, the air chamber is made of high-strength aluminum profile of military quality, wear-resistant and corrosion-resistant, suitable for complex and harsh industrial environments, reasonable and scientific air chamber design, to ensure the accuracy of real-time monitoring of the sensor;
◆ The explosion-proof grade is Exd II CT6, which is certified by the National Explosion-proof Electrical Inspection Center.
EYESKY ES10B11-CH2O(0~10ppm) Formaldehyde Detector Specifications
| LIST | VALUE |
|---|---|
| Detect gas | Formaldehyde CH2O |
| Sensors principle | electrochemistry |
| Sampling method | diffusion |
| CH2O-range | 0~5ppm, 0~10ppm, 20ppm, 50ppm, 100ppm, 200ppm, 500ppm, 1000ppm (optional, unlisted ranges can be customized) |
| CH2O-resolution | 0.01ppm (0-100ppm), 0.1ppm (100-1000ppm), 1ppm (1000ppm or more) |
| CH2O-detection Accuracy | ±3%F.S. |
| Operation mode | Infrared remote control for remote and close operation, easy to set up |
| Repeatability | ≤±1% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| Response time | T90≤20s |
| recovery time | ≤20s |
| Explosion-proof sign | Exd Ⅱ CT6 |
| Protection level | IP66 |
| Output signal | Users can according to the actual site environment requirements, up to 2000 meters (single core 1mm2 Shielding cable) three-wire system 4-20mA current signal output, can be connected to the alarm Controller, PLC, DCS and other Control system (standard configuration) |
| main material | Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber) |
| Installation method | Wall-mounted, pipeline type |
| Operating temperature | -30~60℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Environmental humidity | 10%~95%RH |
| Power Supply | 24VDC (Normal Operating Voltage range 12~ 30VDC) |
| power consumption | 1.5W |
| Operating Pressure | ≤200Kpa |
| Dimension | 180*140*92mm |
| Weight | About 1.6Kg |
| execution standard | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
EYESKY ES10B11-CH2O(0~10ppm) Formaldehyde Detector Packing list
Host x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Influence of hot pressing process and environment parameters on TVOC and formaldehyde release from particle board
- Analysis of Proportional Gas Concentration in Welding Process
- Types of Gas Sensors Used in Safety