EYESKY ES10B01-VOC (0~2000ppm) Fixed VOC Online Detector
EYESKY ES10B01-VOC (0~2000ppm) fixed VOC online Detector adopts British imported Sensors, stable performance, ES10B01-VOC measurement VOC concentration range is 0~2000ppm.
EYESKY-
KORNO MOT500-TVOC-Y Online TVOC Detector 0-500ppm
$ 1751.00 -
KORNO GT1000-VOC-Y Organic solvent volatile gas, alcohol Detector
$ 727.00 -
KORNO MOT500-TVOC-Y air mass /TVOC Detector 0-10PPM
$ 525.00 -
KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
$ 562.00 -
KORNO GT-903-TVOC-Y TVOC Detector, measuring range 0-10PPM
$ 507.00
Introduction
Visionless ES10B01-VOC (0~2000ppm) fixed VOC online Detector is a new one created by Visionless Technology on the basis of ES10AGas Detector, using original imported sensors and new ones32-bit low-power processor; Dashboard display boundarysurface, the value and the progress bar are displayed at the same time, which is beautiful and generous; Circuit adoption4 layers of wiring, against weak signals and anti-dryingDisturbance is stronger; Independent high-precision imports16-bit AD chip and signal processing algorithm to measure data accuracyHigher and more stable;4~20mA, RS485, 200~1000HZ a variety of output signals can be selected, easy to accessAlarm controllers,PLC, DCS and other control systems; Explosion-proof structures are designed to be used in a variety of hazardous industriesLocation; The products are widely used in metallurgy, petroleum and petrochemical, municipal, chemical and other industries.







EYESKY ES10B01-VOC(0~2000ppm) Stationary VOC Detector Specifications
| LIST | VALUE |
|---|---|
| Detection principle | PID photoion |
| Detection method | Fixed online long-term continuous detection, diffusion detection method; fixed online continuous detection, through the external air pump, to achieve pump suction flow detection method (air pump optional); |
| range | 0~2000ppm |
| resolution | 0.01ppm |
| Accuracy | ≤ +/- 2% (Actual concentration, higher Accuracy required according to Sensors performance) |
| Operation mode | Infrared remote control for remote and close operation, easy to set up |
| Repeatability | ≤±0.5% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| Response time | ≤15s(T90) |
| recovery time | ≤ 20 seconds |
| Explosion-proof sign | Exd II CT6 |
| Protection level | IP66 |
| Output signal | Users can according to the actual site environment requirements, up to 2000 meters (single core 1mm2 Shielding cable) current signal 4-20mA output, can be connected to alarm Controller, PLC, DCS and other Control systems (standard configuration) |
| main material | Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber) |
| Installation method | Wall-mounted pipe integrated type (pipe type external thread specification: M45X1.5mm, optional pipe transfer screw joint, can be welded) |
| Operating temperature | -30~60℃ |
| Relative Humidity | ≤ 95% RH, no condensation (Humidity > 90% RH, condensation can be equipped with Filter) |
| Relative Humidity | 10%~95%RH |
| Power Supply | 24VDC (Normal Operating Voltage range 12~ 30VDC) |
| power consumption | 1.5W |
| Working pressure | ≤200Kpa |
| Dimension | 180*140*92mm |
| Weight | About 1.6Kg |
| execution standard | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
EYESKY ES10B01-VOC(0~2000ppm) Stationary VOC Detector Packing list
Host x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- One article includes Coating testing items, instruments, and standards (all)
- What are VOCs? The sources and hazards of VOCs
- Current Situation and Research Direction of VOC Detection Methods in Air
- Brief description of VOC test method in Coating
- Sources, characteristics and hazards of VOCs
- Analysis of Proportional Gas Concentration in Welding Process
- Characteristics of toxic gases and VOC gases in chemical plants
- Types of Gas Sensors Used in Safety
- Learn from the policy orientation of European and American countries on VOC emissions from the Coating Industry
- Water Coatings to Reduce VOCs


ES10B01-VOC(0~2000ppm)