| Protective layer thickness measurement (nominal) range | The first Measurement Range: 6mm~ 90mm; the second Measurement Range: 7mm~ 200mm; |
| Measurement range of steel bar diameter | Ф6~Ф50mm |
| Steel protective layer thickness Measured value MPE | Protective layer thickness first range (nominal) range 6~ 59mm :≤ +/- 1mm; 60~6 9mm :≤ +/- 2mm; 70~90mm :≤ +/- 4mm; protective layer thickness second range (nominal) range 7~ 7 9mm :≤ +/- 1mm; 80~119 mm :≤ +/- 2mm; 120~200mm :≤ +/- 4mm |
| Measured value MPE range | +/- 1st gear |
| Display | 160×128mm |
| Normal operation Environmental requirements | Operating temperature: -10 ℃~ + 40 ℃; Relative Humidity: < 90% RH (no corrosion gas in the air; no strong electromagnetic interference;) |
| Power Supply | Rechargeable battery with a Power Supply time of up to 50 hours |
| Host size | 220×165×90mm |
| Probe Volume | 105×55×30mm |
Warranty days: 1095 days