SMART SENSOR AR8200 CO2 Detector Measurement range 350~9999PPM
SMART SENSOR AR8200 carbon dioxide Detector uses electrochemistry testing principle for testing CO2 concentration, is a portable carbon dioxide Gas Detector, AR8200 carbon dioxide Detector Measurement range 350~9999PPM, Response time < 90s.
-
BH-60-O2 fixed oxygen concentration Detector with display + alarm
$ 196.00 -
KORNO GT-903-CO2-Y Pump Suction Carbon Dioxide Detector 0-500ppm
$ 1016.00 -
Empaer AATL-EX (4G) Pathfinder Series Stationary Gas Detector
$ 384.00 -
HONEYEAGLE HNAG1000-HBR Fixed Hydrogen Bromide Detector 0-100PPM
Login -
SMART SENSOR ST8306 environment Air Quality Detector
$ 185.00
Introduction
Gas Detector is an instrumentation tool for gas leakage concentration detection, mainly referring to portable/handheld Gas Detectors. Gas sensors are used to detect the composition and content of gases. It is generally believed that the definition of a gas sensor is based on the detection target, that is, any sensor used to detect the composition and concentration of a gas is called a gas sensor, regardless of whether it is used by physical or chemical methods. For example, sensors that detect gas flow are not considered gas sensors, but thermal conductivity Gas Analyzers are important gas sensors, although they sometimes use a more or less consistent detection principle.
Technical parameters
Detection of gases | Carbon dioxide (CO²) |
Measuring range | 350~9999PPM |
resolution | 5PPM |
Fundamental error | ± (30PPM+5% READING) |
Response time | ~90 seconds |
Recovery time | <120 seconds |
Sensor principle | Optical principle |
alarm | Sound and light double alarm, the alarm value can be set, and the alarm sound can reach 80 decibels |
Operating ambient temperature | -10~50℃ |
Humidity of the Operating Environment | <95% RH (non-condensing) |
Temperature measurement | Yes |
Packing specifications
power supply | 3.7V lithium battery |
weight | 170 grams |
Product dimensions | 177*63*30mm |
Packing: | Color box packaging |
Standard outer carton capacity | 10 |
Standard outer box size | 44*39*32cm |
Standard outer box gross weight | 9.3kg |
SMART SENSOR Carbon dioxide DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | CO2 |
| Range | 350~9999ppm |
| resolution | 5ppm |
| intrinsic error | +/- (30PPM + 5% reading) |
| Response time | ~90s |
| recovery time | <120s |
| Sensors principle | Optical inspection |
| Alarm mode | Sound, light. |
| Operating temperature | -10~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Temperature measurement | Yes. |
| Power Supply | 3.7V lithium battery |
| Weight | 170 g |
| Dimension | 177*63*30mm |
| Standard outer box Capacity | 10 |
| Packaging Dimensions | 44*39*32cm |
| Gross Weight | 9.3kg |
SMART SENSOR Carbon dioxide Detector Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Tensile specimen preparation: cutting and handling techniques for samples of different materials
- Universal Testing Machine Selection Budget Planning: Different price models performance differences
- Customized Universal Testing Machine Selection: Which Scenarios Need to Be Customized? Customized Process Detailed Explanation
- Universal Testing Machine Fixture Selection: Fixture type recommendation for different material samples
- Universal Testing Machine Selection Pit Avoidance Guide: Don't Ignore These Parameters
- Low Temperature Universal Testing Machine Selection: Requirements for equipment performance in low temperature environment
- Universal Testing Machine in high temperature environment: high-temperature chamber matching and accuracy control
- Large Industrial Universal Testing Machine Selection: Range, Stability and Durability Considerations
- Small Laboratory Universal Testing Machine Selection: Cost-effective Model Recommendation
- Temperature, Humidity and other environmental factors affect the long-term stability of Universal Testing Machine

SMART SENSOR