SMART SENSOR AR8100 oxygen Detector concentration range 0~25%
Measurement range of 0~25% portable oxygen concentration Detector, using Electrochemical sensor principle, AR8100 oxygen Detector test error ≤ +/- 1.5% F · S, Response time ≤ 15 seconds.
-
GUOYUGRA GY/VGD-200-C2HCL3-G (0-50ppm) trichloroethylene Detector
$ 419.00 -
GUOYUGRA GY/VGD-200-C8H10-G Fixed Xylene Detector, infrared detection 0-1% Vol
$ 941.00 -
HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (with display and lamp)
$ 225.00 -
BOSEAN BH-90M-HCl Hydrogen chloride Gas Detector
$ 239.00 -
GUOYUGRA GY/VGD-200-O2-G (0-5% Vol) Industrial Grade, Oxygen Detector
$ 494.00
Introduction
Gas Detector is an instrumentation tool for gas leakage concentration detection, mainly referring to portable/handheld Gas Detectors. Gas sensors are used to detect the composition and content of gases. It is generally believed that the definition of a gas sensor is based on the detection target, that is, any sensor used to detect the composition and concentration of a gas is called a gas sensor, regardless of whether it is used by physical or chemical methods. For example, sensors that detect gas flow are not considered gas sensors, but thermal conductivity Gas Analyzers are important gas sensors, although they sometimes use a more or less consistent detection principle.
Technical parameters
Detection of gases | Oxygen (O2) |
Measuring range | 0~25% |
resolution | 0.1% |
Fundamental error | ≤ ±1.5% F · S |
Response time | ≤ 15 seconds |
Recovery time | ≤ 15 seconds |
Sensor principle | Electrochemical principle The life span is two years |
alarm | Sound and light double alarm, the alarm value can be set, and the alarm sound can reach 80 decibels |
Operating ambient temperature | -10~50℃ |
Humidity of the Operating Environment | <95% RH (non-condensing) |
Temperature measurement | Yes |
Packing specifications
power supply | 3.7V lithium battery |
weight | 170 grams |
Product dimensions | 181*63*30mm |
Packing: | Color box packaging |
Standard outer carton capacity | 10 |
Standard outer box size | 44*39*32cm |
Standard outer box gross weight | 9.4kg |
SMART SENSOR Oxygen DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Oxygen O2 |
| Range | 0~25% |
| resolution | 0.1% |
| intrinsic error | ≤ ±1.5% F·S |
| Response time | ≤15s |
| recovery time | ≤15s |
| Sensors principle | electrochemistry |
| Alarm mode | Sound, light. |
| Operating temperature | -10~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Temperature measurement | Yes. |
| Power Supply | 3.7V lithium battery |
| Weight | 170 g |
| Dimension | 181*63*30mm |
| Standard outer box Capacity | 10 |
| Packaging Dimensions | 44*39*32cm |
| Gross Weight | 9.4kg |
SMART SENSOR Oxygen Detector Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Analysis of the principle, selection and application guide of area measurement instrument
- Freeness Meter Core Technical Knowledge Guide
- Ash muffle furnace: full analysis of principle, application and type selection
- When inks encounter friction - how to protect color boundaries with decolorization testing equipment
- Dust meter detection core and quality control essence
- Smoothness tester core knowledge guide
- UV Analyzer Practical Operation and Knowledge Guide
- Softness tester definition type principle application selection
- Cobb Water Absorbency Tester Type, Principle, Application and Selection Guide
- Coating prepative handmade experts - Lab drawdown blade Film Applicator

SMART SENSOR