SMART SENSOR AS8405 Ammonia Gas Detector Measurement range 0~100PPM
The SMART SENSOR AS8405 ammonia Gas Detector detects ammonia gas and is a portable handheld Gas Detector. The AS8405 ammonia Gas Detector has a Measurement range of 0~100PPM and a resolution of 0.1ppm.
SMART SENSOR-
HUIRUIPU HRP-T1000-CL2 Chlorine Gas Detector (No Display No Light)
$ 204.00 -
GUOYUGRA GY/VGD-200-N2O-G (0-5000ppm) laughing Gas Detector (infrared)
$ 1190.00 -
HONEYEAGLE HNAG1000-HCL Fixed Hydrogen Chloride Detector 0-400PPM
Login -
GUOYUGRA GY/VGD-200-NO2-G (0-200ppm) nitrogen dioxide Detector
$ 692.00 -
KORNO GT-903-Y2 (H2S, EX) standard two-in-one gas alarm
$ 416.00
Introduction
Gas Detector is an instrumentation tool for gas leakage concentration detection, mainly referring to portable/handheld Gas Detectors. Gas sensors are used to detect the composition and content of gases. It is generally believed that the definition of a gas sensor is based on the detection target, that is, any sensor used to detect the composition and concentration of a gas is called a gas sensor, regardless of whether it is used by physical or chemical methods. For example, sensors that detect gas flow are not considered gas sensors, but thermal conductivity Gas Analyzers are important gas sensors, although they sometimes use a more or less consistent detection principle.
Technical parameters
Detection of gases | Ammonia (NH³) |
Measuring range | 0~100PPM |
resolution | 0.1PPM |
Fundamental error | ±2% |
Response time | T90 ≤120 seconds |
Recovery time | ≤120 seconds |
Sensor principle | Electrochemical principle The life span is two years |
alarm | Sound and light double alarm, the alarm value can be set, and the alarm sound can reach 80 decibels |
Operating ambient temperature | -10~50℃ |
Humidity of the Operating Environment | <95% RH (non-condensing) |
Temperature measurement | Yes |
Packing specifications
power supply | 3.7V lithium battery |
weight | 170 grams |
Product dimensions | 181*63*30mm |
Packing: | Color box packaging |
Standard outer carton capacity | 10 |
Standard outer box size | 44*39*32cm |
Standard outer box gross weight | 9.27kg
|
SMART SENSOR AS8405 Ammonia Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Ammonia NH3 |
| Range | 0~100ppm |
| resolution | 0.1ppm |
| intrinsic error | ±2% |
| Response time | T90 ≤120s |
| recovery time | ≤120s |
| Sensors principle | electrochemistry |
| Alarm mode | Sound, light. |
| Operating temperature | -10~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Temperature measurement | Yes. |
| Power Supply | 3.7V lithium battery |
| Weight | 170 g |
| Dimension | 181*63*30mm |
| Standard outer box Capacity | 10 |
| Packaging Dimensions | 44*39*32cm |
| Gross Weight | 9.27kg |
SMART SENSOR AS8405 Ammonia Gas Detector Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.