SMART SENSOR AS8901 oxygen Detector concentration range 0~30%
The SMART SENSOR AS8901 oxygen Detector is a portable oxygen Tester. Measurement range is 0~30%. The intrinsic error of the AS8901 oxygen Detector < +/- 0.1%, and the reaction time is < 50 seconds.
-
HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 400PPM
$ 657.00 -
GUOYUGRA GY/VGD-200-N2-G (0-100% .Vol) nitrogen Detector
$ 220.00 -
BOSEAN GQ-DX101-PH3 Fixed phosphating hydrogen Gas Detector 0~20ppm
$ 257.00 -
GUOYUGRA GY/VGD-200-Xe-G (0-10% Vol) xenon Detector
$ 817.00 -
GUOYUGRA GY/VGD-200-C2H4O-G (0-10ppm) acetaldehyde Detector
$ 692.00
Introduction
Gas Detector is an instrumentation tool for gas leakage concentration detection, mainly referring to portable/handheld Gas Detectors. Gas sensors are used to detect the composition and content of gases. It is generally believed that the definition of a gas sensor is based on the detection target, that is, any sensor used to detect the composition and concentration of a gas is called a gas sensor, regardless of whether it is used by physical or chemical methods. For example, sensors that detect gas flow are not considered gas sensors, but thermal conductivity Gas Analyzers are important gas sensors, although they sometimes use a more or less consistent detection principle.
While many standard Gas Detectors were originally built to detect only one gas, modern multi-purpose or multi-gas detection devices are capable of detecting multiple gases at the same time. Some Gas Detectors can be used as individual units to monitor places with small working space, or can be combined or connected together to form a monitoring and protection system.
Technical parameters
Detection of gases | Oxygen (O2) |
Measuring range | 0~30% |
resolution | 0.1% |
Fundamental error | <±0.1% |
Response time | < 50 seconds |
Recovery time | < 50 seconds |
Sensor principle | Electrochemical principle The life span is two years |
alarm | Sound and light double alarm, the alarm value can be set, and the alarm sound can reach 80 decibels |
Operating ambient temperature | -10~50℃ |
Humidity of the Operating Environment | 15~95%RH |
Packing specifications
power supply | 3.7V lithium battery |
weight | 200 grams |
Product dimensions | 120.2*64.5*38.3mm |
Packing: | Color box packaging |
Standard outer carton capacity | 24 |
Standard outer box size | 46*45.5*55mm |
Standard outer box gross weight | 19.5kg |
SMART SENSOR Oxygen DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Oxygen O2 |
| Range | 0~30% |
| resolution | 0.1% |
| intrinsic error | <±0.1% |
| Response time | <50s |
| recovery time | <50s |
| Sensors principle | electrochemistry |
| Alarm mode | Sound, light. |
| Operating temperature | -10~50℃ |
| Environmental humidity | 15~95%RH |
| Power Supply | 3.7V lithium battery |
| Weight | 200 g |
| Dimension | 120.2*64.5*38.3mm |
| Standard outer box Capacity | 24 |
| Packaging Dimensions | 46*45.5*55mm |
| Gross Weight | 19.5kg |
SMART SENSOR Oxygen Detector Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Analysis of the principle, selection and application guide of area measurement instrument
- Freeness Meter Core Technical Knowledge Guide
- Ash muffle furnace: full analysis of principle, application and type selection
- When inks encounter friction - how to protect color boundaries with decolorization testing equipment
- Dust meter detection core and quality control essence
- Smoothness tester core knowledge guide
- UV Analyzer Practical Operation and Knowledge Guide
- Softness tester definition type principle application selection
- Cobb Water Absorbency Tester Type, Principle, Application and Selection Guide
- Coating prepative handmade experts - Lab drawdown blade Film Applicator

SMART SENSOR