Reader's Guide
This manual is compiled based on manufacturer's data. Due to equipment batch changes, the content may not fully match every physical unit. Please refer to the actual operation and on-device labels.
Copyright belongs to the manufacturer. For internal reference of purchasers only. If safety parameters in the manual differ from the physical unit, please suspend operation and consult our engineer for confirmation.
Disclaimer: This manual is for reference only. In case of any discrepancy, the physical unit shall prevail. Our company assumes no liability for any consequences arising from operations based on this manual.
SMTSER NBC-A200 Flexographic Printing Proof instrument
Flexographic spot color ink sample maker
Flexo ink proofing instrument
User manual
This machine should be parked in a dry place for production, provided with single-phase AC220V power supply, and ensure the ground wire is connected to ensure safe use.
An air supply is required, mainly supplied to the squeegee. Squeegee operating pressure: 0.15-0.2MPa. The printing pressure of this machine is manually adjusted, with fine-tuning by the micrometer to select the pressure.
Printing speed settings: The maximum speed of this machine is 300 rpm (130 meters/minute), with general manufacturers recommending 100-150 revolutions/minute (60 meters/minute).
The flexographic printing plate roller is configured according to the customer's resin plate thickness. The standard thickness of this machine is 1.14 mm, and double-sided tape is 0.38 mm. Customers who wish to change thickness must notify us in advance.
Resin cleaning notes: It is recommended to use a soft-bristled toothbrush for cleaning, and use professional plate washer and a sponge together. If fabric is used for cleaning, fabric fragments will remain on the resin plate.
Notes for cleaning ceramic anilox rollers: Do not use steel wool to wipe it; it is recommended to use a sponge together with professional anilox roller cleaners. If there are water stains, please use a cleaning solution to remove water stains, or ultrasonic cleaning is also an option.
Do not use this device during thunderstorms to avoid damage.
Use the program
The following settings are required: printing pressure, squeegee pressure, speed, number of turns (factory setting: 2 turns per cycle).
Printing material specification: 195×240mm, clamp the material onto the impression roller.
Turn on the machine's power and set the parameters on the touchscreen. If the impression roller is not on the origin (red positioning sensor), you can click "Position" on the touchscreen to automatically find the origin.
First, click "Position" on the touchscreen (ignore if already at the origin), press the squeegee on the roller surface, then click "Squeegee Pressing" on the touchscreen, then click "Ink Evening," and after the anilox roller has rotated 2-3 times, click "Print." After printing, click "Clean" to clean the anilox rollers. For cleaning methods for resin plates and anilox rollers, please refer to the "User Manual."
Operation screen diagram
D Flexo proofing machine by KONYO colour
Managing pages | Parameter set parameters
Rotation number setting: 2 Speed set: 100
Home Page
Home Page | Parameter set parameters
Pressure regulation
Loosen both the M8 screw and the micrometer screw shown in the diagram, then adjust the pressure according to actual needs.
One micrometer circle: 50 um, each small division: 1 um.
After adjusting, tighten the M8 screw and micrometer screw.
Fine adjustment of printing pressure: first loosen these two screws, then rotate the ruler to select the pressure. One round: 50C, each small slot: 1C.
Method of mounting scraper: The opening of the scraper is toward the anilox roll.
Diagram of cleaning tool usage
Flexible resin panel
Toothbrush (soft)
Ceramic anilox rollers
Sponge
Common causes and solutions for flexographic color schemes
| Problems arise | Inspection and solutions |
|---|---|
| 1. Color inconsistent with the printing machine sample | Wipe again with a sponge, toothbrush, and plate washer solution (resin plates cannot be cleaned thoroughly). |
| 2. Color does not match the printing machine sample | Repeatedly clean with anilox roller cleaner (the anilox roller is not thoroughly cleaned) |
| 3. The machine makes abnormal noises | Tighten the bearing housing of the embossing roller, plate printing roller, and anilox roller with a hex key (due to long-term operation vibration, the bearing position may become loose). |
| 4. Printed samples have white spots and blurred edges | Readjust printing pressure and the pressure between the anilox and plate rollers (uneven printing color effect) |
| 5. Uneven ink mixing on the anilox roller | Readjust the squeegee pressure and balance (the anilox roller shows light or dark colors). |
| 6. Uneven printed samples | The anilox roller needs to be independently evenly applied for 2-3 turns before printing (uneven ink mixing) |
| 7. Excessive ink emulsification | Do not use expired ink (expired or improperly stored ink can make it difficult for ink to penetrate the mesh). |
| 8. The touchscreen does not light up when powered on | Check the leakage switch and the relay that contacts the energized circuit, and check the emergency stop switch (the power generator is unresponsive). |
| 9. No response when tapping the touchscreen | Using your fingernail to touch the touchscreen differs from the response of a phone screen (related to screen speed; industrial touchscreens use resistive methods, while mobile screens use capacitive methods). |
| 10. Clicking "Print" doesn't respond? | If the positioning signal is not detected and the servo motor is not detected, click the "Position" button again to restore the signal ![]() |
- 1RONGHUA INSTRUMENT HH-S series digital display thermostatic oil bath instruction manual
- 2SHIMADZU ATX/ATY Series, Electronic Analytical Balance Instruction Manual
- 3AISRY ASR-339A Rubber alcohol Wear resistance tester instruction manual
- 4RONGHUA INSTRUMENT 78-1 Magnetic Stirrer
- 5AISRY ASR-5608 Electric Pencil hardness tester instruction manual
- 6JINGKELIAN QFS Wash Resistance Tester Instruction Manual
- 7AISRY ASR-8503 Side Press/Ring Crushing Test Machine (Button) Instruction Manual
- 8RION VT-06 Viscometer Instruction Manual
- 9EPKMiniTest 70 series, pocket Coating thickness gauge instruction manual
- 10EPKMiniTest 725/735/745 Series Coating thickness gauge instruction manual