HUXI HW-200G/TG microplate incubator instruction manual
Microplate Incubator User Manual
Preface
Thanks to the purchase of the microplate incubator. This user manual includes instrument functions and operating procedures. To ensure correct use, please read the manual carefully before operating the instrument. Please keep the manual safe so you can read it quickly when you encounter problems.
Unboxing inspection
When users open the instrument box for the first time, please check the instrument and accessories against the packing list. If you find any errors, incomplete parts, or abnormalities, please contact the seller or manufacturer.
Table of Contents
Important Notes.... 3
1. Important safety operation information.... 3
2. Safety.... 3
3. Instrument maintenance.... 4
4. After-sales Service.... 4
Chapter 1 Introduction.... 5
Chapter 2 Characteristics.... 6
1. Normal working conditions.... 6
2. Basic Parameters and Performance.... 6
Chapter 3 Basic Operation Instructions.... 7
1. Structural Diagram.... 7
2. Operation panel diagram.... 8
Chapter 4 Operation Guide.... 9
1. Temperature and time settings.... 9
2. Operation and stopping operations.... 9
3. Installation and fixation of microvia plates.... 10
Chapter 5 Fault Analysis and Handling.... 11
Note.... 12
It is important to clarify
1. Important safety operation information
Users need a complete understanding of how the instrument works before safely operating it. Users should carefully read this manual before operating the instrument.

No one is allowed to operate the instrument before reading the manual. If the instructions are not followed, the heat generated during operation may cause severe burns and may result in electric shock accidents. Please carefully read the following safety tips and guidelines, and implement all precautions within them.
2. Safety
During all processes of operating, maintaining, and repairing this instrument, the following basic safety precautions must be followed. Failure to comply with these measures or warnings noted elsewhere in this manual may affect the protection provided by the instrument and the expected scope of its use.

This instrument is a Class I Type B standard equipment compliant with GB9706.1 standards. This instrument is intended for indoor use.

Please read this operation manual carefully before operating this device; otherwise, it may cause personal injury. Only qualified inspectors trained in how to install and use electrical equipment can operate this instrument.

Operators should not attempt to open or repair the instrument, as doing so will disqualify you from warranty coverage and may also result in electric shock. If repairs are needed, our company will be responsible for the repairs.
To prevent electric shock accidents, the instrument's input power cable must be reliably grounded. This instrument uses a three-core grounding plug, with the third pin serving as the grounding pin, which should be used with a grounded power socket.
Before connecting the power supply, ensure the voltage matches the instrument's required voltage. And ensure that the rated load of the power socket is not less than the instrument's requirements.

If the power cord is damaged, it must be replaced. When replacement, the power cord must be replaced with a power cord of the same type and specification. Do not press anything on the power cord during use. Do not place power cords where people are walking.
Always hold the power cord when plugging or unplugging. When plugging in, make sure the plug is fully inserted into the socket; do not forcibly pull the power cord when unplugging.

This instrument should be placed in a place with low humidity, minimal dust, away from water sources, and away from direct sunlight and strong light. The room should be well-ventilated, free from corrosive gases or strong magnetic field interference, and kept away from heating, stoves, and all other heat sources. Do not place the instrument in damp or dusty areas.
The opening on this instrument is designed for ventilation. To avoid overheating, be sure not to block or cover these ventilation holes. When multiple instruments are used simultaneously, the distance between each instrument should be no less than 30cm.

When stopping operation, turn off the power. If the instrument will not be used for a long time, unplug it and cover the instrument with a soft cloth or plastic paper to prevent dust from entering.
In the following situations, immediately unplug the instrument's power cord from the outlet and contact the supplier or have a trained technician handle it:

Liquid spills into the inside of the instrument;
The instrument must be exposed to rain or water;
The instrument is not functioning properly, especially if any unusual sounds or odors appear;
Instrument dropped or casing damaged;
The instrument's functions have changed significantly.
3. Instrument maintenance
This instrument should be regularly cleaned with a clean, soft cloth dampened with a small amount of anhydrous alcohol.
If there are stains on the surface of this instrument, clean it with a soft cloth dipped in cleaning paste.
4. After-sales service
a) Warranty content
Within one month from the date of delivery, our company will be responsible for replacing any faults caused by defects in materials or manufacturing.
This instrument is covered for faults caused by material and manufacturing defects within 12 months from the date of delivery. During the warranty period, our company will selectively repair or replace any instruments found to be defective. Products under warranty must be sent by the user to a repair department designated by our company. The shipping cost for sending the instrument from the user to the maintenance department shall be borne by the user. Our company will cover the shipping costs for returning the instrument to the user.
For repairs outside the warranty period, our company will charge an appropriate repair cost.
b) Warranty coverage
The above warranty is not suitable for damage caused by improper use or maintenance by the user, use under non-compliant conditions, unauthorized repairs, or modifications.
Chapter 1 Introduction
Microplate incubators are formed by combining microprocessing technology with PID control methods. It features a compact size, light weight, and no pollution; Temperature and time LCD display, elegant and easy to operate. Mainly used for microplate labeling plates (96-well/384-well plates), 96-well cell culture plates, and other samples for cell culture and incubation at appropriate temperatures.
This product has the following features:
The LCD displays the system's operating status and parameter values in real time.
Uses high-quality switching power supplies, ensuring stable and reliable long-term operation of the entire machine.
Uses a one-touch knob for operation, simple and easy to use.
It has a power-off recovery function; when the external power supply is cut off and power is restored, the device can automatically resume operation according to the original set program.
Microprocessor control, good temperature control linearity, minimal fluctuations.
The cultivation time can be set arbitrarily within a range of 0~100 hours, and after the scheduled interval ends, an automatic prompt sound is emitted.
Double-layer heating system ensures stability during constant temperature cultivation.
Chapter 2: Characteristics
1. Normal working conditions
Operating temperature: 5°C ~ 30°C
Relative humidity: ≤70%
Power supply: AC220V
2. Basic parameters and performance
| Parameters and performance | |
| Temperature control range | Room temperature +5 °C ~ 80 °C |
| Time setting | 1min ~ 99h59min |
| Temperature control accuracy | ≤ ±0.5 °C |
| Display accuracy | 0.1 °C |
| Module temperature uniformity | ≤ ±0.5 °C |
| Heating time | ≤ 10 minutes (room temperature rises to 80°C) |
| Sample size | 2 microplates or culture plates |
| Heating | Heating film |
| Input power | 120W |
| Dimensions (mm) | 280×270×140 |
| Weight (kg) | 4.0 |
Chapter 3 Basic Operation Instructions
This chapter mainly introduces the instrument's structure, control panel layout, and preparations before powering it on. When using this instrument for the first time, you should familiarize yourself with the contents of this chapter before turning it on.
1. Structural schematic

2. Operation panel diagram

PV: Represents the current system status parameters.
SV: Indicates the current user-set temperature/time parameters. sv 45.0 01:30
START: This indicates that the system is operating according to user-set parameters.
STOP: This indicates the system has stopped running and is in configuration mode.
KEEP: Indicates the user-set runtime as continuous runtime.

Chapter 4: Operation Guide
1. Temperature and time settings
a) Turn on the power switch; the display will display the screen as shown, the instrument will enter initialization, accompanied by a "beep" sound.
b) The system enters parameter configuration mode. The PV displays the real-time temperature value of the heating platform (25.0°C), and STOP means the system has stopped heating and is in configuration mode. At this point, the cursor points to the temperature
c) At this point, a short press of the knob button will rotate the cursor position to the left and select the parameter values you want to adjust. Turn the knob clockwise/counterclockwise to adjust the value.
37.0
2. Operation and stopping operations
a) After setting the parameters, press and hold the knob button (for more than 2 seconds). The system will emit two "beep" prompt sounds, and the system will start running. When the temperature rises to the preset value, the system starts counting down.
b) After the countdown ends, the system stops heating, the instrument begins to cool naturally, and the current heating platform temperature is displayed in real time. At this point, a short press of the knob button will return the system to configuration mode.
Note:In operating mode, press and hold the knob button (for more than 2 seconds) to automatically stop heating and return to configuration mode.
3. Installation and fixation of micro-hole plates
a) Open the cover, angle one end of the micro-hole plate slightly downward toward the spring, and press the spring piece tightly according to the arrow direction
b) Press down the other end of the micro-hole plate in the direction of the arrow.
c) After placing the microporous plate, press down slightly on the bottom surface of the microporous plate and contact the surface of the temperature-controlled plate.
d) Fix another microporous plate using the above method.
Chapter 5 Fault Analysis and Handling
| Serial number | Fault phenomena | Cause analysis | Handling methods |
|---|---|---|---|
| 1 | The display screen does not light up after turning on the power switch | Power is not connected | Check the power supply and turn it on |
| The switch is damaged | Switch switch | ||
| Others | Contact suppliers or manufacturers | ||
| 2 | The temperature display seriously does not match the actual temperature | Sensor damage | Contact suppliers or manufacturers |
| 3 | The LCD screen displays the following message: "Fault Status" "PT-Error!" | Sensor failure | Contact suppliers or manufacturers |
| 4 | The LCD screen displays the following content: "Fault Status" "ADC-Error!" | Data acquisition circuit failure | Contact suppliers or manufacturers |
| 5 | The LCD screen displays the following content: "Fault Status" "Unknown!" | Unknown errors | Restart the instrument or contact the manufacturer |
| 6 | The module does not heat up | Temperature sensor or heater damaged | Contact suppliers or manufacturers |
| 7 | The knob keys are not working | The knob keys are damaged | Contact suppliers or manufacturers |
Note
The contents of this handbook are subject to change without prior notice. If you have any questions, please consult the supplier.
- 1HUXI JB series digital display constant speed powerbasic stirrer instruction manual
- 2HUXI Vortex Series, Instruction Manual for Vortex Mixer
- 3HUXI HT-200 Series Multi-Tube Vortex Mixer Instruction Manual
- 4HUXI HW-400T Microplate Shaker Instruction Manual
- 5HUXI HT-10/HT-20 Track Shaker Instruction Manual
- 6HUXI HX-10 series mini thermostatic metal bath instruction manual
- 7HUXI HX-20T series thermostatic Mixer instruction manual
- 8HUXI HX-20 series, high temperature thermostatic metal bath instruction manual
- 9HUXI HT-W330 Series, Multifunctional Benchtop Shaker Instruction Manual
- 10HUXI HT-X330 Series Multifunctional Benchtop Shaker Instruction Manual