Reader's Guide
This manual is compiled based on manufacturer's data. Due to equipment batch changes, the content may not fully match every physical unit. Please refer to the actual operation and on-device labels.
Copyright belongs to the manufacturer. For internal reference of purchasers only. If safety parameters in the manual differ from the physical unit, please suspend operation and consult our engineer for confirmation.
Disclaimer: This manual is for reference only. In case of any discrepancy, the physical unit shall prevail. Our company assumes no liability for any consequences arising from operations based on this manual.
HUXI Vortex Series, Instruction Manual for Vortex Mixer
Preface
Welcome to the manual for the "Vortex Mixing Device." Users should carefully read this manual before using this instrument, follow the instructions for operation, and understand all precautions. If you encounter any issues or need assistance during installation and use, please contact the manufacturer/supplier's after-sales service department promptly.
Adhering to the philosophy of continuous innovation, our products will be continuously upgraded. This manual is for reference only. If there are any slight changes to the product, no further notice will be given. Thank you for your understanding!
Please keep this manual safe for future reference.
How to get help
If you encounter any issues or need assistance during the installation and use of adjustable/fixed mixers, please contact the manufacturer/supplier's after-sales service department promptly (service hotline: 400-808-1508).
During the after-sales process, please fill in the following information in detail on the warranty card:
Description of problem phenomena.
The methods and operational steps you have taken to solve the problem.
Your phone, fax, email, address, and other contact information.
1. Points to Note
Warning!
Please carefully read this operation manual before operating the instrument and comply with safety operating procedures.
Only professionally trained personnel can operate this instrument.
Safe grounding protection!
☒ To ensure safety, please ensure the power outlet is properly grounded before using this instrument.
☒ When working, please wear protective work clothing; otherwise, the following may pose risks:
Mechanical oscillation forces cause the glass container to break.
Bodies, hair, clothes, and jewelry are all involved.
During manual operation
When using a handheld strut, always hold the instrument firmly with your hand to keep it as stable as possible to prevent movement that could cause liquid to splash.
Keep the sample tube as vertical as possible;
During mixing, please apply the minimum required pressure;
Use accessories when handling multiple samples.
☑ Please place the instrument in a spacious and well-ventilated area, and ensure the workbench is stable, clean, non-slip, dry, and fire-resistant. Do not operate or use this instrument in explosive environments, under hazardous materials, or underwater.
☒ During operation, operate within the indicated area; for continuous operation, operate in the low-speed zone; for jog operations, operate in the high-speed zone.
Before starting work, set the speed control knob to the lowest and gradually increase the speed (adjustable).
If the instrument resonates during oscillation, reduce the speed as soon as possible.
The speed must be reduced in the following situations:
Excessive speed causes liquid to splash;
The instrument rotates unsteadily or starts to move.
☑ Please use the standard accessories listed in the "Accessories" section to ensure safety.
Accessories should be securely installed to prevent the vibrating container from being damaged or thrown out.
☒ Before each work, check whether instruments and accessories are damaged; do not use damaged parts.
When using accessories to shake a single sample, place the shaking container in the center position; when shaking multiple samples, splice and distribute the containers on the accessories.
Avoid using sharp-edged containers that wear out the mixing head.
☑ Before installing accessories, turn off the power.
☒ The instrument will generate heat during use.
Ensure the power supply voltage matches the requirements on the nameplate.
☒ Prevent impact and compression of instruments or accessories.
☒ Only professionally trained personnel may operate this device.
2. Overview of vortex mixing machines
Vortex mixers are widely used in laboratories and laboratories of various universities, research and production enterprises, including environmental monitoring, healthcare, petrochemical, food, and metallurgy, for mixing, homogenizing, and extraction, as well as for stirring liquids. This instrument is not suitable for use in residential areas or under certain restrictions specified in Chapter 1.
3. Inspection
3.1 Unpacking and Inspection of Instrument Quality
If users find any packaging damage, please indicate it on the receipt. If any internal damage is found after opening the package, please contact the manufacturer/supplier.
Note:
If any obvious damage is found on the instrument, do not connect it to a computer.
3.2 Number of Instruments to Check After Unboxing
After receiving the product, please check it according to the packing list. Please keep the instrument packaging materials safe for future repairs upon return to the factory.
4. Model Selection Guide
| Product models | Description |
| VORTEX-M | The mini vortex mixer jogs into operation. Vehicle power can be used. Speed: 3000 RPM |
| VORTEX-1 | The fixed vortex mixer jog with continuous operation. Speed: 2800 RPM |
| VORTEX-2 | Adjustable vortex mixer jog with continuous operation. Rotational speed: 0~2800 RPM |
| VORTEX-1A | Weighted zinc alloy base fixed vortex mixer jog with continuous operation. Speed: 2800 RPM |
| VORTEX-2A | Weighted zinc alloy base adjustable vortex mixer jog with continuous operation. Rotational speed: 0~2800 RPM |
| VORTEX-5 | Weighted zinc alloy base, DC motor, and light-sensing adjustable vortex mixer jog with continuous operation. Rotational speed: 0~2800 RPM |
| VORTEX-5S | Weighted zinc alloy base, DC motor, light sensing, timer adjustable vortex mixer jog with continuous operation. Rotational speed: 0~2800 RPM |
5. Product Display
VORTEX-M
VORTEX-1/1A (same appearance, different base material)
VORTEX-2/2A (same appearance, different base material)
VORTEX-5
| Model | Vortex-5 | Vortex-5S | |||||
| Goods number | 1001016001 | 1001017001 | |||||
| Voltage V | 100~240V | 100~240V | |||||
| Frequency HZ | 50~60 | 50~60 | |||||
| Motor type | DC motor | DC motor | |||||
| Oscillation method | Circumference | Circumference | |||||
| Speed range: rpm | 0~2200 | 100~2200 | |||||
| Speed regulation method | Knob | Button | |||||
| Operating Mode | Jog (light sensing) / continuous | Jog (light sensing) / continuous | |||||
| Timer function | - | Yes | |||||
| Timed range | - | 1~99h59m59s | |||||
| Time display | - | LCD | |||||
| Base material | Zinc alloy | Zinc alloy | |||||
| Turnover diameter mm | 4 | 4 | |||||
| Input power W | 60 | 60 | |||||
| Allowable ambient temperature °C | 5~40 | 5~40 | |||||
| Permissible ambient humidity % | 80 | 80 | |||||
| Instrument size: mm | 165*130*140 | 165*130*140 | |||||
| Packaging size: mm | 250*220*190 | 250*220*190 | |||||
| Net weight of the instrument in kg | 3 | 3 | |||||
| Instrument gross weight in kg | 3.5 | 3.5 | |||||
| Model | VORTEX-M | ||||||
| Goods number | 1001003001 | 1001003002 | 1001003003 | 1001003004 | 1001003005 | 1001003006 | |
| Color | Standard deep blue | Light blue | Pink | Orange | Gray | Black | |
| Turnover diameter mm | 4.5 | ||||||
| Oscillation volume in ml | Max. 80 (1 test tube) | ||||||
| Operating environment | 5-40°C 80%RH Mzx | ||||||
| Power W | 5 | ||||||
| Weight in kg | 0.55 | ||||||
| Oscillation method | Circumference oscillates | ||||||
| Operating Mode | Jok | ||||||
| Test tube diameter | Max. 30 | ||||||
| The vibration and rotation speed increased | 3000 | ||||||
| Appearance dimensions: mm | 92X81 | ||||||
| Protection level | IP43 | ||||||
6. Technical Parameters
| Model | Vortex-1 | Vortex-1A | Vortex-2 | Vortex-2A |
| Goods number | 1001001011 | 1001014001 | 1001002022 | 1001015001 |
| Voltage V | 200~240 optional 100~120 | 200~240 optional 100~120 | ||
| Frequency HZ | 50~60 | 50~60 | ||
| Motor type | Hood-pin motor | Hood-pin motor | ||
| Oscillation method | Circular movement | Circular movement | ||
| Rotation range rpm | 2800 | 0~2800 | ||
| Speed regulation method | - | Knob | ||
| Operating Mode | Jog/continuous | Jog/continuous | ||
| Base material | Aluminum alloy | Zinc alloy | Aluminum alloy | Zinc alloy |
| Turnover diameter mm | 4 | 4 | ||
| Input power W | 60 | 60 | ||
| Output power W | 11 | 11 | ||
| Ambient temperature: °C | 5~40 | 5~40 | ||
| Ambient humidity % | 80 | 80 | ||
| Instrument size: mm | 165*130*140 | 165*130*140 | ||
| Packaging size: mm | 250*220*190 | 250*220*190 | ||
| Net weight of the instrument in kg | 2 | 3.6 | 2 | 3.6 |
| Instrument gross weight in kg | 2.6 | 4 | 2.6 | 4 |
7. Operation
7.1 Usage Mode
7.1.1 VORTEX-M is used by direct pressing
7.1.2 VORTEX-1, VORTEX-2, VORTEX-1A, VORTEX-2A, VORTEX-5, and VORTEX-5S have both continuous and jog modes.
7.2 VORTEX-1/1A/2/2A/5 operation
7.2.1 Continuous Operating Mode
☑ Place the mixer in a safe and stable position, confirm the speed adjustment knob is at zero, and connect to the power supply.
☑ Push the bidirectional switch to the left to the ON position; the work indicator light turns on with POWER and the instrument starts running.
☒ Rotary speed adjustment knob to set the required speed (adjustable).
☑ Push the bidirectional switch to the OFF position to the right; the POWER indicator will turn off, turning off the instrument.
7.2.2 Jog Operation Mode
☑ Place the mixer in a safe and stable position, confirm the speed adjustment knob is at zero, and connect to the power supply.
Push the bidirectional switch to the right to the TOUCH position.
☒ Rotate the adjustment knob to set the required speed (adjustable).
Press the clamp vertically with the test tube, the instrument will start running, and the work indicator light will turn on with POWER.
Push the bidirectional switch to the OFF position to turn off the instrument.
Note:
Test tubes and other containers should be pressed vertically into the center of the oscillator head to ensure smooth operation.
☒ Slowly rotate the motor adjustment knob to ensure smooth instrument operation.
Do not use continuous operation mode in high-speed areas.
7.3 VORTEX-5S Operation
Step 1: Turn on the power (ON/OFF)
Function: Press once to turn on (front panel indicator lights up), press again to turn off (front panel indicator light goes off)
Priority: Highest and always effective.
Button mode: Tap.
Step 2: Mode selection
Function: Press Manual once, then Auto (if not selected, automatic defaults).
Priority: Second, it only works after the power is turned on.
Button mode: Tap.
In automatic mode
Step 3: Parameter Settings (Speed and Time)
speed-up
Function: Speed increase setting (100-2800) can be set. Hold and hold for 3 seconds, value increases by +10; for more than 3 seconds, value increases by +100.
Priority: Third, power is on, works in automatic mode, does not work in manual mode.
Button types: can be tapped or connected.
speed-down
Function: Speed drop setting (2800-100) can be set. Hold and hold for 3 seconds, value decreases by -10; if greater than 3 seconds, value increases by -100.
Priority: Third, power is on, works in automatic mode, but does not in manual mode.
Button types: can be tapped or connected.
time-up
Function: Time rise setting (00h01m00s-99h59m00s) can be set. Hold and hold to increase the value by +1m. When it rises to 59, the minutes no longer change, and the hour increases by +1h.
Priority: Third, power is on, works in automatic mode, but does not in manual mode.
Button types: can be tapped or connected.
time-down
Function: Time decrease setting (99h59m00s-00h01m00s) can be set. Hold and hold without releasing, the value decreases by -1m. When it drops to 1, the minutes no longer change, and the hour decreases by -1h.
* Another function (shutdown): When the time hits 00h000m00s, the machine stops running, so it cannot run without a set time in automatic mode.
Priority: Third, power is on, works in automatic mode, but does not in manual mode.
Button types: can be tapped or connected.
Step 4: Run the device (start/stop)
Function: Click to start, then click again to stop.
Priority: Lowest, power on, manual mode, only activates after time setting. Button mode: Tap.
In manual mode
1. The indicator light on the light-blocking component is on in manual mode;
2. Except for ON/OFF and MODE keys, all other keys are not;
3. If there is an obstruction above the light-shielding component (0-25cm), the indicator light of the light-shielding component will turn off. The equipment will run at 2000rpm; if removed, the indicator light of the light-blocking component will stop working.
4. The display screen also switches to
Manual mode...
speed:2000rpm
VIII. Relevant Standards
The instrument structure meets the following safety standards:
EN-601010-1
The instrument structure complies with the following electromagnetic compatibility standards:
EN 61326-1
9. Maintenance and Cleaning
Proper use and maintenance of the mixer to keep it in good working condition to extend its service life. Keep the instrument clean; never let the solution flow into the machine.
☑ Power must be cut off before maintenance and cleaning; please use our recommended methods to clean the instrument. Removal methods:
| Dyes | Isopropanol |
| Building materials | Aqueous solution with surfactant/isopropanol |
| Cosmetics | Aqueous solution with surfactant/isopropanol |
| Food | Aqueous solution containing surfactants |
| Fuel | Aqueous solution containing surfactants |
For materials not listed, please consult the manufacturer's after-sales service department first.
☒ Before using other cleaning methods, users must confirm with the manufacturer/supplier that these methods will not damage the instrument.
☒ Wear protective gloves when cleaning.
Note:
☒ Electronic devices should not be cleaned with detergents.
This instrument is a precision electronic product; avoid severe vibrations during operation and transportation.
☒ Before sending the instrument for repair, it must be cleaned to avoid contamination by hazardous materials. Please return the instrument to its original packaging box and send it out.
When the product will not be used for a long time, please disconnect the power and store the instrument in a dry, clean, room-temperature, and stable environment.
10. Accessory information
VORTEX-1/2/1A/2A/5/5S accessory information
| Standard information | Name | Number | Description |
![]() | Tightening standard head | 20010047 | Standard head, used for test tubes and small containers with diameters less than 30mm |
![]() | Snap-on standard head | 20010048 | Standard head, used for test tubes and small containers with diameters less than 30mm |
![]() | Hold the support bar | 20010003 | Handheld support rod, used with test tube adapters |
![]() | Universal disc | 20010046 | Universal disc, 100mm round flat rack, compatible with test tube adapters and gaskets. |
![]() | Flat gasket | 20010011 | Flat gasket, used in combination with φ 100 universal round head, suitable for test tubes or small containers with diameters less than 99mm |
![]() | 4 wells, 50ml | 20010039 | 4-hole test tube adapter, compatible with φ100 universal round head and handheld strut, 4-hole, 50ml test tube |
![]() | 8 wells, 10 & 15 ml | 20010041 | 8-hole test tube adapter, used with φ100 universal round head and handheld strut for 8-well, 10/15ml test tubes |
![]() | 8 wells, 5ml | 20010042 | 8-hole test tube adapter, uses 8-well, 5ml test tubes in conjunction with φ100 universal round head and handheld struts |
![]() | 12 wells, 1.5 & 2 ml | 20010040 | 12-well test tube adapter, used with φ100 universal round head and handheld support rod, 12-well 1.5/2ml test tube |
![]() | 24 wells, 0.5ml | 20010043 | 24-well test tube adapter, used with φ100 universal round head and handheld support rod, 24-well, 0.5ml test tube |
![]() | 48 wells, 0.2ml | 20010044 | 48-well test tube adapter, compatible with φ100 universal round head and handheld strut, 48-well, 0.2ml test tube |
11. Application
11.1 VORTEX-1/1A/2/2A accessories
| Attachment | Fixed type | Adjustable | ||
| Standard configuration | Optional | Standard configuration | Optional | |
| Standard head | ✓ | ✓ | ||
| Handheld support rod + 48 holes 6mm | ✓ | ✓ | ||
| Handheld strut + 15 holes 10mm | ✓ | ✓ | ||
| Handheld support rod + 12 holes 12mm | ✓ | ✓ | ||
| Handheld support rod + 12 holes 14mm | ✓ | ✓ | ||
| Handheld support rod + 8 holes 16mm | ✓ | ✓ | ||
| Handheld support rod + 8 holes 20mm | ✓ | ✓ | ||
| φ100+平板垫片 | ✓ | |||
| φ100+48Holes6mm | ✓ | |||
| φ100+15Holes10mm | ✓ | |||
| φ100+12Holes12mm | ✓ | |||
| φ100+12Holes14mm | ✓ | |||
| φ100+8Holes16mm | ✓ | |||
| φ100+8Holes20mm | ✓ | |||
| φ100+4Holes26mm | ✓ | ✓ | ||
11.2 VORTEX-M Accessories
| Serial number | Name | Quantity |
| 1 | Main unit | 1 unit |
| 2 | Certificate of conformity and warranty card | 1 copy |
| 3 | Manual | 1 copy |
- 1HUXI HT-200 Series Multi-Tube Vortex Mixer Instruction Manual
- 2HUXI HW-400T Microplate Shaker Instruction Manual
- 3HUXI HT-10/HT-20 Track Shaker Instruction Manual
- 4HUXI HX-10 series mini thermostatic metal bath instruction manual
- 5HUXI HX-20T series thermostatic Mixer instruction manual
- 6HUXI HX-20 series, high temperature thermostatic metal bath instruction manual
- 7HUXI HT-W330 Series, Multifunctional Benchtop Shaker Instruction Manual
- 8HUXI HT-X330 Series Multifunctional Benchtop Shaker Instruction Manual
- 9HUXI HF-1L Inverter Speed Regulation Glass Reaction Kettle Instruction Manual
- 10HUXI MS-D50/100 Vertical Digital Display Large Capacity Magnetic Stirrer Instruction Manual