SHANGFEN 721G visible spectrophotometer album

SHANGFEN 721G visible spectrophotometer album covers 722N, 721N, 722G, 721G series models, using microcomputer control and Holographic grating monochromator, introducing Wavelength range, transmittance error and other technical indicators, suitable for laboratory qualitative and quantitative analysis.

722N / 721N

Visible spectrophotometer
722N/721N main unit    

This product uses microprocessor control technology to perform qualitative and quantitative analysis of substances within the visible spectral range, making it an essential multipurpose analytical instrument in conventional laboratories.

Main features

Monochromat      

Holographic shimmering grating monochromator features high wavelength accuracy, good monochromaticity, and low stray light.

Large screen display      

The extra-large screen with a backlit LCD display makes measurement data clear at a glance.

Microcomputer measurement systems      

Microcomputer measurement system with high T-A conversion accuracy, automatic adjustment of 0% (T) and 100% (T), supports concentration factor setting and direct reading.

Stability schematic      

Measurement readings are highly accurate, with excellent reproducibility and stability.

Technical Specifications

Wavelength range        
Wavelength range
325nm ~ 1000nm (722N)
360nm ~ 1000nm (721N)
Wavelength error        
Maximum allowable wavelength error
±2nm
Wavelength repeatability        
Wavelength repeatability
≤ 1nm
Transmission ratio error        
Maximum allowable error of transmission ratio
± 0.5% (T) (measured in NBS930D)
Transmittance ratio repeatability        
Transmittance ratio repeatability
≤ 0.2% (T)
Spectral bandwidth        
Spectral bandwidth
4nm
Stray light        
Stray light
≤ 0.1% (T) (360nm, NaNO₂) (722N)
≤ 0.15% (T) (360nm, NaNO₂) (721N)
Stability        
Stability
Dark current drift: 0.2% (T) / 3min
Bright current drift: 0.5% (T) / 3min
Power supply        
Power / Power
AC220V±22V 50Hz±1Hz (722N)
AC85V~242V (721N)
Power: 80W

Optional

Printer      Software    
Serial printer
Dedicated analysis software
722G series    

722G / 721G-100 / 721G / 721 visible spectrophotometers

This series of visible spectrophotometers uses microprocessor control technology to perform qualitative and quantitative analysis of substances within the visible spectral range. It is an essential multipurpose analytical instrument in conventional laboratories, applied in medical and health departments, clinical testing, biochemistry, petrochemicals, factories and mines, environmental protection, quality control, and teaching laboratories in colleges and universities.

Backlit LCD display to avoid reading errors caused by pointers.

Main features

Backlit LCD display Uses a backlit LCD display for clear and precise readings.      
Monochromat Holographic Brilliant Grating C-T monochromator features high wavelength accuracy, good monochromaticity, and low stray light.      
Microcomputer measurement systems Microcomputer measurement system with high T-A conversion accuracy, automatic adjustment of 0% (T) and 100% (T), direct concentration reading, and concentration factor setting.      
Stability Measurement readings are highly accurate, with excellent reproducibility and stability.      

Technical Specifications

WavelengthWavelength range
340nm~1000nm (721G、721G-100、721)
325nm~1000nm (722G)
Wavelength repeatabilityMaximum allowable wavelength error
±2nm
Transmission ratio errorMaximum allowable error of transmission ratio
±0.5% (T)
RepeatabilityTransmittance ratio repeatability
≤0.2% (T)
Spectral bandwidthSpectral bandwidth
5nm
Stray lightStray light
≤0.5% (T) (360nm, NaNO₂)
StabilityStability
Dark current drift: 0.2% (T) / 3min
Bright current drift: 0.5% (T) / 3min
Power supplyPower supply voltage
AC220V ±22V 50Hz±1Hz
Power: 80W

Features of the 721G-100 spectrophotometer

Features of the 721G-100      Same as the 721G model, but the main difference is a widened test sample chamber and a standard 10cm cuvette designed specifically for low-concentration solutions in the sugar industry, power plants, water plants, chemical industries, and other industries.    

Optional

Printer      Software      Serial printer ·  Dedicated analysis software