TENLIN GDH-0506 High Accuracy Low Temperature Circulating Bath

TENLIN GDH-0506 High Accuracy Low Temperature Circulating Bath album, covering DC, BD, GDH and other series, showing temperature control technology, resolution up to 0.001 ℃, suitable for thermostatic testing in biological, chemical and other fields.

Constant temperature bath

Product Introduction

It is widely used in higher education institutions, enterprise quality inspection, and production departments in industries such as biology, chemical engineering, chemistry, pharmaceuticals, life sciences, and physical property testing. It provides users with a controlled hot and cold source with uniform and constant temperature, allowing for constant temperature experiments or testing of experimental samples or produced products. It can also serve as a heat or cold source for direct heating or cooling as well as auxiliary heating or cooling.

Product features

  • ✔ Independently developed temperature control technology, high-standard PT100, and fully imported electronic components

  • ✔ The software system can correct the discrepancy between the displayed temperature and the actual temperature

  • ✔ Large LCD screen with a resolution up to 0.01°C

  • ✔ Over-temperature protection and over-temperature alarm can automatically cut off loads

  • ✔ Timer function: automatically cuts off load by setting the total duration

  • ✔ Hidden cooling coil design increases tank space

  • ✔ PID intelligent self-tuning with manually adjustable parameters

  • ✔ The software digitally locks system settings to prevent accidental operation

  • ✔ High-efficiency fully enclosed compressor refrigeration with multiple protections

  • ✔ Internal and external circulation function, with an external circulation interface of 10mm

  • ✔ Supports non-standard customization

Optional Accessories (Partial)

Level protection system            RS485 communication interface            Multi-point correction function            External PT100            Bracket        

1. DC vertical low-temperature constant temperature bath

ModelTemperature range (°C)Resolution (°C)Degree of Fluctuation (±°C)External dimensionsPower (kW)Tank Volume (L)Slot opening (mm)Groove Depth (mm)Pump flow rate (L/min)
DC-0506-5~1000.010.03320*370*6750.87.5180*1601506
DC-1006-10~1000.010.03320*370*6750.97.5180*1601506
DC-2006-20~1000.010.03320*370*6751.07.5180*1601506
DC-3006-30~1000.010.03320*370*7651.57.5180*1601506
DC-4006-40~1000.010.03400*450*9402.17.5180*1601506
DC-4506-45~1000.010.03400*450*9402.27.5180*1601506
DC-0510-5~1000.010.03320*370*7651.310180*1602006
DC-1010-10~1000.010.03320*370*7651.510180*1602006
DC-2010-20~1000.010.03320*370*7651.810180*1602006
DC-3010-30~1000.010.03400*450*9402.010180*1602006
DC-4010-40~1000.010.03400*450*9402.110180*1602006
DC-0515-5~1000.010.03320*370*7652.115250*1602006
DC-1015-10~1000.010.03320*370*7652.215250*1602006
DC-2015-20~1000.010.03320*370*7652.315250*1602006
DC-3015-30~1000.010.03400*450*9402.415250*1602006
DC-4015-40~1000.010.03450*540*9902.515250*1602006
DC-0520-5~1000.010.05400*450*10402.320250*1603006
DC-1020-10~1000.010.05400*450*10402.420250*1603006
DC-2020-20~1000.010.05400*450*10402.520250*1603006
DC-3020-30~1000.010.05400*450*10402.620250*1603006
DC-4020-40~1000.010.05450*540*10902.720250*1603006
DC-0530-5~1000.010.05450*540*9902.530330*28023013
DC-1030-10~1000.010.05450*540*9902.630330*28023013
DC-2030-20~1000.010.05450*540*9902.730330*28023013
DC-3030-30~1000.010.05450*540*9902.730330*28023013
DC-4030-40~1000.010.05450*540*10903.030330*28023013

2. DC vertical ultra-low temperature constant temperature bath

ModelTemperature range (°C)Resolution (°C)Degree of Fluctuation (±°C)External dimensionsPower (kW)Tank Volume (L)Slot opening (mm)Groove Depth (mm)
DC-6006-60-1000.010.05660*660*12503.27.5180*160150
DC-7006-70-1000.010.05660*660*13503.37.5180*160150
DC-8006-80-1000.010.05660*660*13503.57.5180*160150
DC-6010-60-1000.010.05660*660*12503.410180*160200
DC-7010-70-1000.010.05660*660*13503.510180*160200
DC-8010-80-1000.010.05660*660*13503.610180*160200
DC-6015-60-1000.010.05660*660*12503.515250*160200
DC-7015-70-1000.010.05660*660*13503.615250*160200
DC-8015-80-1000.010.05660*660*13503.715250*160200
DC-6020-60-1000.010.05660*660*13503.720250*160300
DC-7020-70-1000.010.05660*660*14503.820250*160300
DC-8020-80-1000.010.05660*660*14503.920250*160300
DC-6030-60-1000.010.05Consultation4.030330*280230
DC-7030-70-1000.010.05Consultation4.230330*280230
DC-8030-80-1000.010.05Consultation4.530330*280230

3. BD high-precision low-temperature constant temperature bath

ModelTemperature range (°C)Resolution (°C)Degree of Fluctuation (±°C)External dimensionsPower (kW)Volume (L)Slot opening (mm)Groove Depth (mm)Cyclic method
BD-0506-5~1000.0010.005-0.01320*370*6750.86180*150150Internal circulation
BD-1006-10~1000.0010.005-0.01320*370*6750.96180*150150Internal circulation
BD-2006-20~1000.0010.005-0.01320*370*6751.06180*150150Internal circulation
BD-0510-5~1000.0010.005-0.01320*370*7651.310180*150200Internal circulation
BD-4015-40~1000.0010.005-0.01400*450*9402.515250*160200Internal circulation
BD-0520-5~1000.0010.005-0.01400*450*10402.320250*160300Internal circulation
BD-4030-40~1000.0010.005-0.01450*540*10903.030330*280230Internal circulation

4. GDH high-precision low-temperature constant temperature bath

ModelTemperature range (°C)Resolution (°C)Degree of Fluctuation (±°C)External dimensionsPower (kW)Volume (L)Slot opening (mm)Groove Depth (mm)Cyclic method
GDH-0506-5~1000.0010.005-0.02320*370*6750.86180*160150Internal circulation
GDH-1010-10~1000.0010.005-0.02320*370*7651.510180*160200Internal circulation
GDH-2015-20~1000.0010.005-0.02320*370*7652.315250*160200Internal circulation
GDH-4030-40~1000.0010.005-0.02450*540*10903.030330*280230Internal circulation

5. DCW horizontal low-temperature constant temperature tank

ModelTemperature range (°C)Resolution (°C)Degree of Fluctuation (±°C)External dimensionsPower (kW)Tank Volume (L)Slot opening (mm)Groove Depth (mm)Pump flow rate (L/min)
DCW-0506-5-1000.010.03650*400*5200.87.5180*1601506
DCW-1006-10-1000.010.03650*400*5200.97.5180*1601506
DCW-2006-20-1000.010.03650*400*5201.07.5180*1601506
DCW-0510-5-1000.010.03650*400*5201.310180*1602006
DCW-3015-30-1000.010.03650*400*5202.415250*1602006

6. HX low-temperature constant temperature circulator

Temperature range: -40~100°C
Pump flow rate: 13L/min

7. SC High-precision constant temperature tank

Temperature range: RT+10~300°C
Category: Type A/B

8. GX high-temperature circulator

Temperature range: RT~300°C
Capacity: 5~50L

9. DCW-L magnetic stirring tank

Equipped with magnetic stirring function
Speed: 0-1000 rpm

10. DC-C program-controlled low-temperature constant temperature tank

Programmable linear temperature control
Adjustable heating and lowering speed

The above is an overview of the series. For more detailed specifications (HX series, SC series, GX series, magnetic stirring tanks, programmatic temperature control series), please refer to the corresponding electronic selection manual according to the model list.