![]() Model selection comparator
If you have any questions, please click below
|
![]() Elcometer A456CFBI2 Coating Thickness Gauge
In coming
United KingdomDetail
|
![]() DongRu DR5000S Coating Thickness Gauge
1200.0 RMB
ChinaDetail
|
|---|
| Principle | Magnetic | Magnetic | |||
|---|---|---|---|---|---|
| Substrate | Ferrous | Ferrous | |||
| Range | 0 ~ 6000μm | 0 ~ 6000μm | |||
| Precision | ±1% ±2% ±3% | ±3% | |||
| Certificate | With certificate | Without | |||
| Probe | Integrated probe | Integrated probe | |||
| Application | General | ||||
| Accessories | |||||
| Measurement principle | magnetic Induction | Magnetic Induction | |||
|---|---|---|---|---|---|
| Measurement range | 0~5000μm | 0 ~ 5000μ m | |||
| margin of error | ±1~3%/±20μm | ±3% | |||
| resolution | 1μm|10μm | ||||
| Minimum measurement surface | 8mm | 18*15mm | |||
| Minimum radius of curvature | Convex 4mm; Concave 25mm | Convex 5mm; Concave 25mm | |||
| thinnest substrate | |||||
| probe | Integrated probe | ||||
| Calibrated Certificate | Yes. | ||||
| Probe size | |||||
| Probe line length | |||||
| Probe material | |||||
| Probe Weight | |||||
| Calibrated mode | Factory calibrated, two point calibrated, zero point calibrated, single point calibrated | ||||
| Measurement mode | |||||
| Unit display | μm | ||||
| statistical function | Number of readings, average value, standard deviation, minimum limit, maximum limit, coefficient of variation | ||||
| icon function | |||||
| Interface | USB | ||||
| Data storage | Last 5 Measured values | ||||
| Power Supply | 2 AA batteries, rechargeable batteries can also be used | ||||
| Standards | AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12,BS 5599,EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83) | ||||
| system language | |||||
| Display screen | 2.4 " (6 cm) QVGA color TFT display, 320x240 pixels | ||||
| Operating temperature | 80℃-10~50℃ | 0℃-50℃ | |||
| Relative Humidity | 20~90%RH | ||||
| Operating temperature | 80℃-10~50℃ | 0℃-50℃ | |||
| Voltage prompt | |||||
| Battery life | With 1 reading per second, it can work continuously for up to 24h | ||||
| Protection level | IP64 | ||||
| supporting software | ElcoMaster ® Software | ||||
| Weight | 161G (including battery) | ||||
| Dimension | 141*73*37mm | ||||
Friendly reminder: This page is a comparison of Elcometer A456CFBI2,DongRu DR5000S.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about Elcometer A456CFBI2,DongRu DR5000Ssimilarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.