![]() Model selection comparator
If you have any questions, please click below
|
![]() Elcometer A456CFNFBS Coating Thickness Gauge
In coming
United KingdomDetail
|
![]() Ipre CT400 Coating Thickness Gauge
1180.0 RMB
ChinaDetail
|
|---|
| Principle | Difunctional Magnetic Eddy current | Difunctional | |||
|---|---|---|---|---|---|
| Substrate | Ferrous Non-Ferrous | Ferrous Non-Ferrous | |||
| Range | 0 ~ 800µm 0 ~ 1500m 0 ~ 2000m 0 ~ 6000μm > 6000μm | 0 ~ 1500m | |||
| Precision | ±1% ±2% ±3% | ±3% | |||
| Certificate | With certificate | Without | |||
| Probe | Split probe | Split probe | |||
| Application | General | General | |||
| Accessories | Body | ||||
| Measurement principle | Magnetic Induction + eddy Current | Magnetic Induction, eddy Current | |||
|---|---|---|---|---|---|
| margin of error | Depending on the probe | ±3% | |||
| resolution | Depending on the probe selected | 0.1μm|1μm | |||
| Minimum measurement surface | Depending on the probe | ||||
| Minimum radius of curvature | Depending on the probe selected | ||||
| thinnest substrate | |||||
| probe | split | ||||
| Calibrated Certificate | Yes. | ||||
| Probe size | |||||
| Probe line length | |||||
| Probe material | |||||
| Probe Weight | |||||
| Calibrated mode | Factory calibrated, two point calibrated, zero point calibrated, single point calibrated | ||||
| Measurement mode | |||||
| Unit display | μm/mils | ||||
| statistical function | Number of readings, average value, standard deviation, minimum limit, maximum limit, coefficient of variation | ||||
| icon function | |||||
| Interface | USB | ||||
| Data storage | Last 5 Measured values | ||||
| Power Supply | 2 AA batteries, rechargeable batteries can also be used | ||||
| Standards | AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12,BS 5599,EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83) | ||||
| system language | |||||
| Display screen | 2.4 " (6 cm) QVGA color TFT display, 320x240 pixels | ||||
| Operating temperature | 80℃-10~50℃ | ||||
| Relative Humidity | |||||
| Operating temperature | 80℃-10~50℃ | ||||
| Voltage prompt | |||||
| Battery life | With 1 reading per second, it can work continuously for up to 24h | ||||
| Protection level | IP64 | ||||
| supporting software | ElcoMaster ® Software | ||||
| Weight | 161G (including battery) | 230g | |||
| Dimension | 141*73*37mm | 125mmx67mmx33mm | |||
Friendly reminder: This page is a comparison of Elcometer A456CFNFBS,Ipre CT400.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about Elcometer A456CFNFBS,Ipre CT400similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.