![]() Model selection comparator
If you have any questions, please click below
|
![]() Elcometer A456CNSS Coating Thickness Gauge
In coming
United KingdomDetail
|
![]() PHYNIX Surfix SX-N1.5 Coating Thickness Gauge
Login
GermanyDetail
|
|---|
| Principle | Eddy current | Eddy current | |||
|---|---|---|---|---|---|
| Substrate | Non-Ferrous | Non-Ferrous | |||
| Range | 0 ~ 800µm 0 ~ 1500m 0 ~ 2000m 0 ~ 6000μm > 6000μm | 0 ~ 1500m | |||
| Precision | ±1% ±2% ±3% | ±2% | |||
| Certificate | With certificate | With certificate | |||
| Probe | Split probe | Split probe | |||
| Application | General | General | |||
| Accessories | Body | ||||
| Measurement principle | eddy Current | Eddy Current | |||
|---|---|---|---|---|---|
| margin of error | Depending on the probe | ±1μm/2% | |||
| resolution | Depending on the probe selected | ||||
| Minimum measurement surface | Depending on the probe | 10x10mm | |||
| Minimum radius of curvature | Depending on the probe selected | Convex: 5mm; Concave: 50mm | |||
| thinnest substrate | 0.5mm(F);0.05mm(N) | ||||
| probe | split | built-in | |||
| Calibrated Certificate | Yes. | ||||
| Probe size | Φ14*83mm | ||||
| Probe line length | |||||
| Probe material | Carbide cutter head | ||||
| Probe Weight | 70g | ||||
| Calibrated mode | Factory calibrated, two point calibrated, zero point calibrated, single point calibrated, zero point offset, preset calibrated, Automatic calibration | Factory zero calibrated | |||
| Measurement mode | |||||
| Unit display | μm/mils | μm | |||
| statistical function | Number of readings, average value, standard deviation, minimum limit, maximum limit, coefficient of variation | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation | |||
| icon function | |||||
| Interface | USB、Bluetooth | USB 2.0 | |||
| Data storage | 1500 Measured values | Up to 1000 readings | |||
| Power Supply | 2 AA batteries, rechargeable batteries can also be used | 2 AAA batteries | |||
| Standards | AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12,BS 5599,EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83) | DIN、ISO、ASTM、BS | |||
| system language | |||||
| Display screen | 2.4 " (6 cm) QVGA color TFT display, 320x240 pixels | High resolution color display | |||
| Operating temperature | 80℃-10~50℃ | 0 ℃ to + 50 ℃ | |||
| Relative Humidity | |||||
| Operating temperature | 80℃-10~50℃ | 0 ℃ to + 50 ℃ | |||
| Voltage prompt | |||||
| Battery life | With 1 reading per second, it can work continuously for up to 24h | ||||
| Protection level | IP64 | IP52 | |||
| supporting software | ElcoMaster ® Software | Yes. | |||
| Weight | 161G (including battery) | ||||
| Dimension | 141*73*37mm | ||||
Friendly reminder: This page is a comparison of Elcometer A456CNSS,PHYNIX Surfix SX-N1.5.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about Elcometer A456CNSS,PHYNIX Surfix SX-N1.5similarities and differences, please refer to the NBCLab product details.