![]() DGC DC-3020C Thickness Gauge
9520.0 RMB
ChinaDetail
|
![]() DGC DC-4000 Thickness Gauge
13520.0 RMB
ChinaDetail
|
|---|
| Measurable Materials | The material itself | The material itself Coating | |||
|---|---|---|---|---|---|
| Measuring Range | 0~400mm | 0~400mm | |||
| Error | 0.1% Miscellaneous | Miscellaneous | |||
| Calibration Certificate | No certificate | No certificate | |||
| Probe Type | Split probe | Integrated probe | |||
| Application environment | high temperature | high temperature | |||
| Coating Penetration | |||||
| Accessories | |||||
| Measuring range | T~E:0.65~400mm;E~E:3.0~25mm | T~E:1.4~200mm;E~E:3.0~25mm | |||
|---|---|---|---|---|---|
| Probe frequency | 5MHz | 5MHz | |||
| Probe style | Split probe (D5301), dual crystal | Split probe (D5301 penetrating coating probe) | |||
| Probe contact temperature | <60℃ | <60℃ | |||
| Measurement error | ± 0.04mm (Film thickness value < 9.99mm) ± (0.1% Film thickness value < 0.04) mm Film thickness value = 10~99.9mm; ± 0.3% Film thickness value Film thickness value > 100mm | ||||
| Display resolution | 0.01mm/0.001inch | ± 0.1mm (measurement greater than 100mm), ± 0.01mm (measurement less than 100mm) | |||
| Measurement mode | T-E, E-E two measurement modes | Standard, MIN Minimum, Difference Value, Average, Upper and Lower Limit Settings | |||
| Sound speed range | 1000~9999m/s | 1000~9999m/s | |||
| Display | 320 * 240 color display | 320X240 four-bit color TFT dot matrix liquid crystal display | |||
| Operating language | Chinese | Chinese | |||
| Application software | without | without | |||
| Operating Temperature | -20~50℃ | -20~50℃ | |||
| Storage temperature | -20~50℃ | -20~50℃ | |||
| Power | 2 * AA battery | 2 * 7 AAA battery | |||
| Host size | 115*64*27mm | 133*75*29mm | |||
| Weight | 220G (including battery) | 260G (including battery) | |||
| Measurement speed | Ordinary measurement 2 times/second; high-speed measurement 10 times/second | Ordinary measurement 2 times/second; high-speed measurement 10 times/second | |||
| Upper/Lower limits | √ | ||||
| Storage Capacity | 5200 | ||||
| Data output | Software Free | ||||