| Type | desktop | desktop | |||
|---|---|---|---|---|---|
| Ion Type | I | I | |||
| consumables | |||||
| Ion Measurement Range | 5×10-8~1M | ||||
|---|---|---|---|---|---|
| Ion measurement Accuracy | ±1% F.S | ±1% F.S | |||
| Display resolution | 0.001, 0.01, 0.1, 10.1℃ | ||||
| Ion calibrated point | 2 to 5 point | 2 to 5 point | |||
| Ion measurement mode | Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L | |||
| mV range | -2000~2000mV | -1999.9~1999.9mV | |||
| mV measurement Accuracy | ±0.2mV | ±0.2mV | |||
| mV Display resolution | 0.1mV | ||||
| mV calibrated point | 1 point (only for R.mV mode) | ||||
| mV measurement mode | Relative or absolute mV | ||||
| Temperature Measurement Range | 0~105℃, 32~221℉ | ||||
| Temperature measurement Accuracy | ±0.5℃ | ±0.5℃ | |||
| Display resolution | 0.001, 0.01, 0.1, 10.1℃ | ||||
| Temperature calibrating point | 1 point | 1 point | |||
| Temperature unit | ℃/℉ | ℃/℉ | |||
| Temperature compensation range | 0~100℃, 32~212℉ | ||||
| Temperature compensation method | Manual/Automatic | ||||
| data lock | Manual or automatic end point locking | Manual or automatic end point locking | |||
| Data stability condition | Standard or high-precision | Fast or high precision | |||
| Calibrated reminder | 1 to 31 days or closed | 1 to 31 days or closed | |||
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off | ||||
| One-click reset function | contain | contain | |||
| data storage | 1000 sets | ||||
| Interface | USB | ||||
| Connector | BNC | BNC | |||
| Display | 7-Inch TFT LCD | Customized LCD (130 × 110mm) | |||
| Power supply type | DC12V power adapter | ||||
| Dimensions | 240*200*80*mm | 210*188*60*mm | |||
| Instrument Weight | 1.7kg | ||||
| Optional | Ionic standard solution, ionic strength regulator, TP-10K temperature probe | ||||
| Packaging Dimensions | 300*240*170mm | 300*240*170mm | |||
| Encasement Weight | 2kg | 1.7kg | |||