Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Colorimeter> 3NH> Compare
      Model selection comparator
      If you have any questions, please click below
      3NH YS6010 Desktop Colorimeter
      Login
      ChinaChina
      Detail
      3NH TS8216(Φ0.3mm) Desktop Colorimeter
      In coming
      ChinaChina
      Detail
      Model comparison
      Type Portable Benchtop
      Measurement method Contact Contact
      Measurement Aperture F4mm F8mm F4mm
      Light source Pulsed xenon lamp LED light source LED light source UV light source
      Integrating sphere > F40mm > F40mm
      Color Repeatability ≤0.02
      Aperture Shape plane plane
      software computer software computer software
      Special features Fluorescence measurement
      Parameter comparison
      Lighting method Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; includes UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; Haze (ASTM D1003)
      Sensors 256-Pixel dual array CMOS image sensor
      Measuring range
      lighting source 360~780Nm combined LED light source, 400nm cut-off light source
      Measurement time About 2.4s (about 5s for simultaneous SCI/SCE testing)About 3s (about 6s for simultaneous SCI/SCE testing) Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing)
      Measurement caliber 反射:Φ30mm/Φ25.4mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm;透射:Φ30mm/Φ25.4mm Reflection: φ 0.3mm Transmission: φ 4mm
      Sexual repeability
      Operating language Simplified Chinese, Traditional Chinese, English Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish)
      Data Interface USB, print serial port
      Viewing Angle CIE 2 ° / 10 ° 2°/10°
      Observation light source D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
      Color difference formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
      Data storage 2000 master standards and 20,000 samples (SCI/SCE counts as one data)
      Power mode
      Operating conditions 0~40℃(32~104°F)
      Storage environment -20~50℃
      Dimensions 370*300*200mm
      Weight Approx. 9.6kg About 9.6kg
      Standards IE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7
      Integrating sphere size F154mm Φ154mm
      Spectroscopic method Concave grating spectroscopy
      Wavelength range 360~780nm
      wavelength spacing 10nm
      Light spectrum half bandwidth 10nm
      Reflectance Measurement Range 0~200% 0~200%
      Light-containing method Reflection SCI/SCE, Transmission SCI/SCE Reflection SCI/SCE, Transmission SCI/SCE
      Color space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
      Chromaticity indicator WI, YI, TI, homochromatic index MI, dip lightfastmess, color fastness, force, coverage, cobalt-platinum index, Gardner index, 8 degree glossiness, 555 hue classification
      display mode Light spectrum graphs/data, sample chromatic values, color difference values/graphs, chromaticity graphs, Color simulation, Pass/Fail results, Color bias Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias
      Measurement time About 2.4s (about 5s for simultaneous SCI/SCE testing)About 3s (about 6s for simultaneous SCI/SCE testing) Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing)
      Spectral reflectance repeability Φ25.4mm/SCI, standard deviation within 0.05% (400~700nm: within 0.04%)
      Chromatic value repeability Φ25.4mm / SCI, ΔE * from 0.02<--sep--0/> <--sep--0/> Φ25.4mm / SCI, ΔE * from 0.03<--sep--0/> <--sep--0/>
      Spectral transmittance, sexual repeability Φ25.4mm/SCI, standard deviation within 0.05% (400~700nm: within 0.04%)
      Inter-station difference ΔE * from < 0.15
      Power DC 24V, 2A power adapter Power
      Lighting source life 5 years more than 3 million measurements More than 3 million measurements in 5 years

      Friendly reminder: This page is a comparison of 3NH YS6010,3NH TS8216(Φ0.3mm).NBCLab only provides you with the similarities and differences of the product in the model and specifications.

      For more information about 3NH YS6010,3NH TS8216(Φ0.3mm)similarities and differences, please refer to the NBCLab product details.

      Focus on online sales of Lab Testing Instruments