| Type | Fixed | Portable | |||
|---|---|---|---|---|---|
| Number of Gases | Single gas | Single gas | |||
| Sensors | Electrochemistry | Electrochemistry | |||
| Gases | Miscellaneous | Miscellaneous | |||
| Sampling Mode | Diffusion Pump | Diffusion Pump | |||
| Detect gas | N2 | N2 | |||
|---|---|---|---|---|---|
| Range | 0~100% .vol is only suitable for on-site measurement of pure nitrogen | ||||
| resolution | 0.01%vol | ||||
| Response time | T90≤20s | T90 ≤30s | |||
| Linearity | ≤±1% | ||||
| detection Accuracy | ≤±3% | ||||
| Zero drift | ≤ +/- 1% (F. S/year) | ||||
| recovery time | ≤20s | ||||
| Repeatability | ≤±1% | <3% | |||
| expansion gas | Supports 1-6 Sensors (optional) | ||||
| Explosion-proof sign | CNEx16.0547 | Exd ib ⅡC T4 Gb | |||
| Protection level | IP65 | IP66 | |||
| production license | Guangdong 00001052 (CMC metrology authentication) | ||||
| Humidity | Optional accessories, temperature detection range: -40~120 ℃, Humidity detection range: 0~100% RH | ||||
| Sampling method | Diffusion, flow, pump suction optional | Pump suction, diffusion | |||
| Installation method | Wall-mounted, pipeline, circulation | ||||
| Operating temperature | -30~50℃ | -30~70 ℃ (conventional gas), -20~50 ℃ (toxic gas) | |||
| Environmental humidity | 0~95% RH non-condensing | 10~90% RH non-condensing | |||
| Operating Pressure | 0~100Kpa | 86~106kPa | |||
| Power Supply | 24VDC(12~30VDC) | Built-in high-performance imported core lithium battery, nominal Voltage: 3.7VDC, 2500mAh | |||
| Dimension | 200*149*79mm | 135*65*35mm | |||
| Weight | 1.5Kg | About 0.46Kg | |||
| execution standard | GB3836.1-2010、GB3836.2-2010 | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 | |||
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal④ Optional 4-20mA + Hart output ⑤ switching signal | ||||
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal④ Optional 4-20mA + Hart output ⑤ switching signal | ||||
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional | ||||
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional | Sound and light alarm, two-color LED alarm light, sound ≥ 75dB@25cm | |||
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion | ||||
Friendly reminder: This page is a comparison of KORNO MOT500-N2-Y,EYESKY ES20B-N2.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about KORNO MOT500-N2-Y,EYESKY ES20B-N2similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.