Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> ElektroPhysik> Compare
      Model selection comparator
      If you have any questions, please click below
      ElektroPhysik MiniTest 4500 Coating Thickness Gauge
      In coming
      GermanyGermany
      Detail
      LinShang LS225 + F500 + Rack Coating Thickness Gauge set
      5160.0 RMB
      ChinaChina
      Detail
      Model comparison
      Principle Magnetic Eddy current Magnetic
      Substrate Ferrous Non-Ferrous Ferrous
      Range 0 ~ 200m 0 ~ 800µm 0 ~ 1500m 0 ~ 2000m 0 ~ 6000μm > 6000μm 0 ~ 800µm
      Precision ±2%
      Certificate Without
      Probe Split probe Split probe
      Application General Small piece
      Accessories
      Parameter comparison
      Measurement principle magnetic induction
      Measurement range
      margin of error ± (0.3 μm + 2%) five-point calibrated
      resolution 0.1mm | 1mm
      Minimum measurement surface F7mm
      minimum curvature
      thinnest substrate
      probe
      Probe size F15 * 110mm
      Probe line length
      Probe material
      Probe Weight 81g
      Calibrated Certificate
      Calibrated mode Factory calibrated, zero and up to four calibrated points, if no substrate is used, calibrated by coating (CTC) Support zero point calibrate, 1 point to 5 point calibrate
      Alarm function Optical and audible signal alarms when limits are exceeded
      Unit display μm/mm/cm/mils/inch
      statistical function kvar, n, max., min. kvar, n, max., min
      compensation function Used to add/subtract a constant value from a reading
      Interface USB and Bluetooth 4.0
      Data storage 200W, can be grouped over 9500
      Power Supply 3 * AA (LR06) battery, USB
      Standards DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882; ISO 19840; ASTM B 244, B 499, D 7091, E376 GB/T 4956-2003、DIN EN ISO 2808、JJG-818-2005、
      system language
      Display screen 53 x 46 mm, backlit 240X160 dot matrix LCD
      Operating temperature -10~60℃
      Storage temperature -20~70℃ -20℃~60℃
      Operating Conditions
      Voltage prompt
      Battery life 150 hours (without backlighting)
      Protection level IP65
      supporting software
      Weight 320G (including battery)
      Dimension 153*89*36mm

      Friendly reminder: This page is a comparison of ElektroPhysik MiniTest 4500,LinShang LS225 + F500 + Rack.NBCLab only provides you with the similarities and differences of the product in the model and specifications.

      For more information about ElektroPhysik MiniTest 4500,LinShang LS225 + F500 + Racksimilarities and differences, please refer to the NBCLab product details.

      Focus on online sales of Lab Testing Instruments