| Type | handheld | handheld | |||
|---|---|---|---|---|---|
| Hardness system | HL HB HRA HRB HRC HV HS p b | HL HB HRA HRB HRC HV HS | |||
| Accessories | |||||
| Error of indication | ±2HL/HRC0.2 (0.3% @ HL=800) | ||||
|---|---|---|---|---|---|
| Display | 2.8-Inch 320x240 TFT color large-screen graphic LCD display, suitable for display in sunlight | 240 × 160 dot matrix LCD | |||
| Hardness system | HLD/HRC/HRB/HB/HV/HSD/HRA/σb | ||||
| Measurement range | HL170~960、HRC17~70、HRB13~109、HB20~655、HV80~940、HS32~99.5、HRA30~88、σb(rm)255~2639N、mm2 | HLD (170-960); HV (83-976); HB (30-651); HRC (17.6-68.5); HS (26.4-99.5); HRB (13.5-100); HRA (60-85.8) | |||
| Impact device | Wireless D probe or wired D probe (standard)/DC/D + 15/C/G/E/DL (optional) | ||||
| Measurement material | 11 Common Metal Materials | ||||
| Data storage | 7 Arrays of 100 Measured values with corresponding time, operator, sample number, etc | ||||
| statistics | Single group analysis: mean, MAX Maximum, MIN Minimum, range, standard deviation, kurtosis coefficient, skewness coefficient, pass rate, Measured value distribution histogram, Measured value normal distribution inspection, Measured value uniform distribution inspectionTwo-group analysis: mean significant difference inspection, standard deviation significant difference inspection, pass rate significant difference inspection, distribution significant difference inspection | ||||
| statistics | Single group analysis: mean, MAX Maximum, MIN Minimum, range, standard deviation, kurtosis coefficient, skewness coefficient, pass rate, Measured value distribution histogram, Measured value normal distribution inspection, Measured value uniform distribution inspectionTwo-group analysis: mean significant difference inspection, standard deviation significant difference inspection, pass rate significant difference inspection, distribution significant difference inspection | ||||
| prompt | Upper and lower limit alarm/low Voltage prompt/beep tone prompt | ||||
| Communication interface | 2.4G wireless/Bluetooth/USB/RS232 connection to PC or printer, USB interface for charging wireless probe | ||||
| Working time | > 40 hours | ||||
| Power Supply | 4 1.5V5 AA dry batteries/1.2V nickel-metal hydride rechargeable batteries/3.7 lithium batteries | 2 AA alkaline dry batteries | |||
| Operating temperature | -10~+45℃ | ||||
| Dimensions | 195*84*38mm | ||||
| Net Weight | 550g | ||||
| meet the standard | Compliant with GB/T 17394-1998, ASTM A956, DIN50156 standards | ||||