| Min-TEMP | -60℃ | -60℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤40%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | >800L | >800L | |||
| TEMP fluctuation | ±0.5℃ | ±0.5℃ | |||
| Humidity deviation | ±2% ±3% | ±2% | |||
| Interior size | 1000*1000*1000mm | 1000*1000*1000mm | |||
|---|---|---|---|---|---|
| Temperature range | -60~150℃ | -60~150℃ | |||
| Humidity control range | 30~98%R.H | 20~98%R.H | |||
| Temperature fluctuation | ≤±0.5℃ | ||||
| Humidity Deviation | +2、-3%R.H | ±2%R.H | |||
| Heating rate | -20→100℃≈35min;-40→100℃≈45min | ≧3℃/min | |||
| Cooling rate | 25~-40℃≈50min;25~-60℃≈65min | ||||
| display | (7.0 inch) large screen screen programmable touch temperature and humidity Controller | ||||
| Accuracy range | Setting Accuracy: temperature ± 0.1 ℃, humidity ± 1% R.H | ||||
| Temperature transducer | Platinum resistance PT100Ω/MV | ||||
| Heating system | Fully independent system, nickel-chromium alloy electric heating heater | Nickel chromium alloy stainless steel heating device | |||
| Humidification system | Built-in isolated, all stainless steel shallow surface evaporative humidifier | Stainless steel humidifier | |||
| Dehumidification system | Adopt evaporator coil dewpoint temperature laminar flow contact dehumidification method | ||||
| Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method | 1 imported French Taikang fully enclosed compressorMechanical binary refrigeration method | |||
| Circulatory system | Temperature-resistant and low-noise air-conditioned motor, multi-leaf centrifugal wind turbine | ||||
| Enclosure Material | A3 steel plate electrostatic spray treatment | SUS304 #stainless steel plate (1.0mm thick) | |||
| Inner box material | SUS304 stainless steel high quality mirror steel plate | SUS304 #stainless steel plate (1.0mm thick) | |||
| Thermal insulation material | Polyurethane Rigid Foam, Ultrafine Glass Fiber Cotton | 100mm polyurethane rigid foam + 100mm high density fiberglass cotton | |||
| Door frame insulation | Double Layer High and Low Temperature Conditioning Silicone Rubber Door Seal | ||||
| Timer | 0~9999 M, H adjustable | ||||
| Standard configuration | Multi-layer heating and defrosting with lighting Glass window 1 set, 2 test racks, 1 test lead hole φ50mm | ||||
| Safety Devices | Leakage, short circuit, over temperature, water shortage, motor overheating, compressor overVoltage, overload, overcurrent protection | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc | |||
| Power | AC220V ± 10% 50Hz AC380V ± 10% 50Hz three-phase five-wire system | 380V | |||
| Environment temperature | 5~30℃ | ||||
| Environment humidity | ≤85%R.H | ||||
| Temperature Uniformity | ≤+2℃ | ±2℃ | |||