![]() Model selection comparator
If you have any questions, please click below
|
![]() 3NH YL4520 Non-contact Colorimeter
Login
ChinaDetail
|
![]() 3NH YL4668 Non-contact Colorimeter
Login
ChinaDetail
|
|---|
| Type | Benchtop | Benchtop | |||
|---|---|---|---|---|---|
| Measurement method | Contactless | Contactless | |||
| Measurement Aperture | Miscellaneous | Miscellaneous | |||
| Light source | LED light source | LED light source UV light source | |||
| Integrating sphere | |||||
| Color Repeatability | ≤0.05 | ≤0.03 | |||
| Aperture Shape | plane curved surface powder particle liquid paste | plane powder liquid paste | |||
| software | No software | computer software | |||
| Special features | Fluorescence measurement | ||||
| Lighting method | 45/0 (45 annular uniform illumination 0 ° reception); | D/8 (diffuse illumination, 8 ° direction reception, SCI includes specular light); conforms to standards CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | |||
|---|---|---|---|---|---|
| lighting source | Light spectrum LED light source | Light spectrum LED light source, UV light source | |||
| Spectroscopic method | Concave grating spectroscopy | Concave grating spectroscopy | |||
| sensor | 256-Pixel dual array CMOS image sensor | 256-Pixel dual array CMOS image sensor | |||
| Wavelength range | 400~700nm | ||||
| Reflectance Measurement Range | 0~200% | 0~200% | |||
| Measurement caliber | F20mm | Φ20mm (can be customized Φ10mm) | |||
| Non-contact measurement distance | 7.5mm | ||||
| Sample height | 0~150mm | Film thickness unlimited, use only test probe | |||
| Distance adjustment method | Manual adjustment (test height can be stored) | Fixed height according to actual sample | |||
| Measurement mode | sample modeSingle measurement, average measurement (2~ 99 times) | Software customization capabilities (additional customization capabilities to be evaluated) | |||
| Positioning method | Camera positioning | Camera positioning | |||
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | |||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter),DINΔE99 | |||
| Chromaticity indicator | WI, YI, TI, homochromatic index MI, lightfastmess, color fastness, force, coverage | ||||
| Viewing Angle | CIE 2 ° / 10 ° | 2°/10° | |||
| Observation light source | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) | |||
| display mode | Light spectrum map/data, sample chromatic value, color difference value/map, chromaticity map, Color simulation, pass/fail results, display tolerance can be set | Light spectrum graph/data, sample chromatic value, color difference value/graph, Color simulation, pass/fail results, display tolerance can be set | |||
| Measurement time | About 1.5s | Fastest 0.2s | |||
| Data storage | 30,000 sample mode + quality control mode; 10,000 continuous statistics mode | ||||
| Spectral reflectance repeability | Standard deviation within 0.08% | ||||
| Inter-station difference | ΔE * from < 0.25 | ΔE * from < 0.2 | |||
| Measurement mode | sample modeSingle measurement, average measurement (2~ 99 times) | Software customization capabilities (additional customization capabilities to be evaluated) | |||
| Dimensions | 330*250*370mm | ||||
| Weight | About 10Kg | About 3Kg (test probe only) | |||
| Power | DC 24V, 3A power adapter Power | ||||
| Lighting source life | 5 years more than 3 million measurements | 5 years more than 3 million measurements | |||
| Display | TFT true color 7inch, capacitive touch screen | TFT true color 7inch, capacitive touch screen | |||
| Data Interface | USB/RS-232 | USB, Bluetooth ® 5.0 | |||
| Operating language | Simplified Chinese, English, Traditional Chinese | Simplified Chinese, Traditional Chinese, English | |||
| Operating conditions | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m | ||||
| Storage environment | -20~50 ℃, 0~85% RH (no condensation) | ||||
| Chromatic value repeability | ΔE * ab within 0.05 | ||||
Friendly reminder: This page is a comparison of 3NH YL4520,3NH YL4668.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about 3NH YL4520,3NH YL4668similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.