![]() Model selection comparator
If you have any questions, please click below
|
![]() 3NH TS10A Colorimeter
In coming
ChinaDetail
|
![]() 3NH TS20 Colorimeter
Login
ChinaDetail
|
|---|
| Type | Portable | Portable | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F8mm | F8mm | |||
| Light source | LED light source | LED light source | |||
| Integrating sphere | ≤ F40mm | ≤ F40mm | |||
| Color Repeatability | ≤0.1 | ≤0.08 | |||
| Aperture Shape | plane | plane | |||
| software | Mobile APP | computer software | |||
| Special features | |||||
| Lighting method | D/8 (diffuse illumination, 8 ° direction reception) SCI measurement conforms to standard CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | D/8 (diffuse illumination, 8 ° direction reception) SCI measurement conforms to standard CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | |||
|---|---|---|---|---|---|
| Integrating sphere size | Φ40mm | F40mm | |||
| Lighting source | Light spectrum LED Light source | ||||
| spectroscopy | Plane grating spectroscopy | ||||
| Sensor | Silicon photodiode array (dual row 24 groups) | ||||
| Wavelength range | 400~700nm | 400~700nm | |||
| wavelength interval | / | ||||
| Light spectrum Bandwidth | 10nm | ||||
| Reflectance Measurement Range | L: 0~100 reflectance: can test the reflectance at a specific wavelength specified by the user (default 550nm) | L: 0~100 reflectance: can test the reflectance at 3 specific wavelengths specified by the user (default 440nm, 550nm, 600nm) | |||
| Measurement caliber | Φ8mm | F8mm | |||
| Light-containing method | SCI | SCI | |||
| Color Space | CIE LAB,XYZ,Yxy,LCh | ||||
| Color difference formula | ΔE*ab,ΔE*00 | ΔE * ab, ΔE * 00 | |||
| Chroma indicator | / | ||||
| Viewing Angle | CIE 10° | CIE 10 ° | |||
| Available Light Sources | D65,A,F2(CWF) | ||||
| display mode | Reflectance (user specified 1 specific wavelength reflectance), sample chromatic value, color difference value/graph, pass/fail result, Color simulation, Color bias | Reflectance (user-specified reflectance at 3 specific wavelengths), sample chromatic value, color difference value/graph, pass/fail result, Color simulation, Color bias | |||
| Display Accuracy | 0.01 | ||||
| Measurement time | About 1.5s | About 1.5s | |||
| Repeatability of chromatic value | MAV/SCI,ΔE*ab 0.1以内 | ||||
| Inter-instrument Agreement | ΔE*ab<0.4(MAV/SCI) | ||||
| Measurement mode | Single measurement, average measurement (2~ 99 times) | Single measurement, average measurement (2~ 99 times) | |||
| positioning method | Stabilizer positioning | ||||
| Dimensions | 81*71*214mm | 81*71*214mm | |||
| Weight | Approx. 460g | About 460g | |||
| Battery life | Lithium battery, 6000 cycles in 8 hours | Lithium battery, 6000 times in 8 hours | |||
| Lighting source life | More than 3 million measurements in 5 years | 5 years more than 3 million measurements | |||
| Display | TFT true color 3.5inch, capacitive touch screen | TFT true color 3.5inch, capacitive touch screen | |||
| Interface | Bluetooth ® 5.0, USB charging only, does not support QC software | ||||
| data storage | 500 master standards and 10,000 samples | ||||
| Operating language | Simplified Chinese, English, Traditional Chinese | Simplified Chinese, English, Traditional Chinese | |||
| Operating environment | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m | ||||
| Storage environment | -20~50 ℃, 0~85% RH (no condensation) | -20~50 ℃, 0~85% RH (no condensation) | |||
Friendly reminder: This page is a comparison of 3NH TS10A,3NH TS20.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about 3NH TS10A,3NH TS20similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.