      Model comparison
      Type Portable
      Measurement method Contact
      Measurement Aperture F4mm F8mm
      Light source LED light source UV light source
      Integrating sphere ≤ F40mm
      Color Repeatability ≤0.05
      Aperture Shape plane curved surface
      software computer software
      Special features Fluorescence measurement
      Parameter comparison
      Lighting method D/8 (diffuse illumination, 8 ° direction reception) SCI/SCE measurement conforms to CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 8°/d
      Integrating sphere size Φ40mm F40mm
      lighting source Light spectrum LED light source, UV light source Light spectrum LED light source
      spectroscopy Plane grating spectroscopy
      Sensor Silicon photodiode array (dual row 32 groups)
      Wavelength range 400~700nm 400~700nm
      wavelength interval 10nm
      Light spectrum half bandwidth 10nm
      Reflectance Measurement Range L: 0~120 reflectance: 0~200%
      Measurement caliber Dual diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm F4mm
      Light-containing method Simultaneous testing of SCI/SCE SCI
      Color space CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,DIN Lab9,DIN Lab99 Munsell(C/2) CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99(部分仅在APP实现)
      color difference formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99
      Chroma indicator WI, YI, homochromatic index MI, colour fastness, color fastness, force, coverage, Formula Guide
      Viewing Angle CIE 2°/10° CIE 2 ° / 10 °
      observation light source D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
      display mode Light spectrum plots/data, sample chromatic values, color difference values/plots, pass/fail results, Color simulation, Color bias Sample chromatic value, color difference value/plot, pass/fail result, Color simulation, Color bias
      Display Accuracy 0.01
      Measurement time Approximately 1.5 seconds (approximately 3.2 seconds for simultaneous SCI/SCE testing) About 1.2s
      Chromatic value repeability MAV/SCI, Delta E * ab 0.05 or less ΔE * ab within 0.1
      stand-alone difference ΔE*ab<0.3(MAV/SCI)
      measurement mode Single measurement, average measurement (2~ 99 times)
      positioning method camera positioning, stabilizer positioning
      Dimensions 81*71*214mm 205*67*80mm
      Weight About 460g Approx. 500g
      battery life Lithium battery, 6000 cycles in 8 hours
      Lifetime of lighting source More than 3 million measurements in 5 years
      Display TFT true color 3.5inch, capacitive touch screen TFT True Color 2.8inch @(16:9)
      Data Interface USB, Bluetooth ® 5.0 USB; Bluetooth 5.0; buttons
      data storage 1000 master standards, 30,000 samples (one data can include SCI/SCE at the same time)
      operating language Simplified Chinese, English, Traditional Chinese
      Operating environment 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m
      Storage environment -20~50 ℃, 0~85% RH (no condensation) -20~50 ℃, 0~85% RH (no condensation)