![]() Model selection comparator
If you have any questions, please click below
|
![]() 3NH YS6080 Desktop Colorimeter
Login
ChinaDetail
|
![]() EVERFINE HACA-3800 High Precision Color Analyzer
Login
ChinaDetail
|
|---|
| Type | Benchtop | Benchtop | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F4mm F8mm Miscellaneous | Miscellaneous | |||
| Light source | Pulsed xenon lamp | ||||
| Integrating sphere | > F40mm | ||||
| Color Repeatability | ≤0.01 | ≤0.1 | |||
| Aperture Shape | plane powder particle liquid paste | ||||
| software | computer software | ||||
| Special features | haze test | ||||
| Lighting method | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement; haze (ASTM D1003); | ||||
|---|---|---|---|---|---|
| Integrating sphere size | F154mm | ||||
| lighting source | 360~780Nm xenon lamp, 400nm cut-off xenon lamp, 420nm cut-off xenon lamp, 460nm cut-off xenon lamp | ||||
| Spectroscopic method | Concave grating spectroscopy | ||||
| sensor | 256-Pixel dual array CMOS image sensor | ||||
| Wavelength range | 360~780nm | ||||
| wavelength spacing | 10nm | ||||
| Light spectrum half bandwidth | 5nm | ||||
| Reflectance Measurement Range | 0~200% | 0~200%; resolution: 0.01% | |||
| Measurement caliber | 反射:Φ30mm/Φ25.4mm,Φ18mm/Φ15mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm;透射:Φ30mm/Φ25.4mm | ||||
| Light-containing method | Reflection SCI/SCE, Transmission SCI/SCE | ||||
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | ||||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | ||||
| Chromaticity indicator | WI, YI, isochromatic index MI, lightfastmess, fastness to color change, force, coverage, APHA, Hazen, Pt-Co (platinum cobalt index), Gardner index, 8 degrees glossiness, 555 hue classification, haze (ASTM D1003), Saybolt (Seibert index) | ||||
| Viewing Angle | CIE 2 ° / 10 ° | ||||
| Observation light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | ||||
| display mode | Light spectrum graphs/data, sample chromatic values, color difference values/graphs, chromaticity graphs, Color simulation, Pass/Fail results, Color bias | ||||
| Measurement time | About 2.4s (about 5s for simultaneous SCI/SCE testing) | ||||
| Inter-station difference | ΔE * from < 0.12 (SCI) | ||||
| Dimensions | 370*300*200mm | 315Mm × 310mm × 680mm (width × height × length) | |||
| Weight | Approx. 9.6kg | About 32kg | |||
| Power | DC 24V, 3A power adapter Power | AC100V~240V 50/60Hz | |||
| Lighting source life | More than 3 years 500,000 measurements | ||||
| Display | TFT true color 7inch, capacitive touch screen | ||||
| Data Interface | USB, Bluetooth ® 4.0, print serial port | ||||
| Data storage | 5000 master standards and 40,000 samples (SCI/SCE counts as one data) | ||||
| Operating language | Simplified Chinese, English, Traditional Chinese | ||||
| Operating conditions | 0~40℃(32~104°F) | ||||
| Storage environment | -20~50℃ | 0 ℃~ 40 ℃, Relative Humidity ≤ 80%, no condensation | |||
| Standards | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 | ||||
| Spectral reflectance repeability | Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.05%) | ||||
| Sexual repeability 2 | Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.012 (after the instrument is preheated and corrected, the average value of the whiteboard is measured 30 times at intervals of 5s) | ||||
| Sexual repeability 3 | Spectral transmittance: Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.06%): | ||||
| Sexual repeability 4 | Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.015 (after instrument preheating correction, the average value of 30 whiteboard measurements at intervals of 5s | ||||
Friendly reminder: This page is a comparison of 3NH YS6080,EVERFINE HACA-3800.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about 3NH YS6080,EVERFINE HACA-3800similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.