![]() Model selection comparator
If you have any questions, please click below
|
![]() 3NH YS6003 Desktop Colorimeter
Login
ChinaDetail
|
![]() 3NH TS8216(Φ0.3mm) Desktop Colorimeter
In coming
ChinaDetail
|
|---|
| Type | Benchtop | Benchtop | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F4mm F8mm | F8mm | |||
| Light source | LED light source | LED light source UV light source | |||
| Integrating sphere | > F40mm | > F40mm | |||
| Color Repeatability | ≤0.01 | ≤0.02 | |||
| Aperture Shape | plane powder particle liquid paste | plane | |||
| software | computer software | computer software | |||
| Special features | Fluorescence measurement haze test | Fluorescence measurement | |||
| Lighting method | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement; haze (ASTM D1003); | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; includes UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; Haze (ASTM D1003) | |||
|---|---|---|---|---|---|
| Integrating sphere size | F154mm | Φ154mm | |||
| lighting source | 360~780Nm combined LED light source (5 million life) | ||||
| Spectroscopic method | Concave grating spectroscopy | ||||
| sensor | 256-Pixel dual array CMOS image sensor | ||||
| Wavelength range | 360~780nm | ||||
| wavelength spacing | 10nm | ||||
| Light spectrum half bandwidth | 5nm | ||||
| Reflectance Measurement Range | 0~200% | 0~200% | |||
| Measurement caliber | 反射:Φ30mm/Φ25.4mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm;透射:Φ30mm/Φ25.4mm | Reflection: φ 0.3mm Transmission: φ 8mm | |||
| Light-containing method | Reflection SCI/SCE, Transmission SCI/SCE | Reflection SCI/SCE, Transmission SCI/SCE | |||
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | ||||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | |||
| Chromaticity indicator | WI, YI, isochromatic index MI, lightfastmess, fastness to color change, force, coverage, APHA, Hazen, Pt-Co (platinum cobalt index), Gardner index, 8 degrees glossiness, 555 hue classification, haze (ASTM D1003), Saybolt (Seibert index) | ||||
| Viewing Angle | CIE 2 ° / 10 ° | 2°/10° | |||
| Observation light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | ||||
| display mode | Light spectrum graphs/data, sample chromatic values, color difference values/graphs, chromaticity graphs, Color simulation, Pass/Fail results, Color bias | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias | |||
| Measurement time | About 2.4s (about 5s for simultaneous SCI/SCE testing) | Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing) | |||
| Inter-station difference | ΔE * from < 0.15 | ||||
| Dimensions | 370*300*200mm | ||||
| Weight | Approx. 9.6kg | About 9.6kg | |||
| Power | DC 24V, 3A power adapter Power | ||||
| Lighting source life | 5 years more than 3 million measurements | More than 3 million measurements in 5 years | |||
| Display | TFT true color 7inch, capacitive touch screen | TFT true color 7inch, capacitive touch screen | |||
| Data Interface | USB, print serial port | ||||
| Data storage | 1000 master standards, 20,000 samples (SCI/SCE counts as one data) | ||||
| Operating language | Simplified Chinese, English, Traditional Chinese | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) | |||
| Operating conditions | 0~40℃(32~104°F) | ||||
| Storage environment | -20~50℃ | ||||
| Standards | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 | ||||
| Spectral reflectance repeability | Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.05%) | ||||
| Sexual repeability 2 | Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.01 (after the instrument is preheated and corrected, the average value of the whiteboard is measured 30 times at intervals of 5s) | ||||
| Sexual repeability 3 | Spectral transmittance: Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.06%) | ||||
| Sexual repeability 4 | Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.015 (after the instrument is preheated and corrected, the average value of the whiteboard is measured 30 times at intervals of 5s) | ||||
Friendly reminder: This page is a comparison of 3NH YS6003,3NH TS8216(Φ0.3mm).NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about 3NH YS6003,3NH TS8216(Φ0.3mm)similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.