Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Colorimeter> 3NH> Compare
      Model selection comparator
      If you have any questions, please click below
      3NH YS6003 Desktop Colorimeter
      Login
      ChinaChina
      Detail
      3NH TS8216(Φ0.5mm) Desktop Colorimeter
      In coming
      ChinaChina
      Detail
      Model comparison
      Type Benchtop Benchtop
      Measurement method Contact Contact
      Measurement Aperture F4mm F8mm F8mm
      Light source LED light source LED light source UV light source
      Integrating sphere > F40mm > F40mm
      Color Repeatability ≤0.01 ≤0.02
      Aperture Shape plane powder particle liquid paste plane
      software computer software computer software
      Special features Fluorescence measurement haze test Fluorescence measurement
      Parameter comparison
      Lighting method Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement; haze (ASTM D1003); Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; includes UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; Haze (ASTM D1003)
      Integrating sphere size F154mm Φ154mm
      lighting source 360~780Nm combined LED light source (5 million life)
      Spectroscopic method Concave grating spectroscopy
      sensor 256-Pixel dual array CMOS image sensor
      Wavelength range 360~780nm
      wavelength spacing 10nm
      Light spectrum half bandwidth 5nm
      Reflectance Measurement Range 0~200% 0~200%
      Measurement caliber 反射:Φ30mm/Φ25.4mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm;透射:Φ30mm/Φ25.4mm Reflection: φ 0.5mm Transmission: φ 4mm
      Light-containing method Reflection SCI/SCE, Transmission SCI/SCE Reflection SCI/SCE, Transmission SCI/SCE
      Color space CIE LAB,XYZ,Yxy,LCh,CIE   LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
      Color difference formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,   DINΔE99,ΔE(Hunter) ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
      Chromaticity indicator WI, YI, isochromatic index MI, lightfastmess, fastness to color change, force, coverage, APHA, Hazen, Pt-Co (platinum cobalt index), Gardner index, 8 degrees glossiness, 555 hue classification, haze (ASTM D1003), Saybolt (Seibert index)
      Viewing Angle CIE 2 ° / 10 ° 2°/10°
      Observation light source D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
      display mode Light spectrum graphs/data, sample chromatic values, color difference values/graphs, chromaticity graphs, Color simulation, Pass/Fail results, Color bias Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias
      Measurement time About 2.4s (about 5s for simultaneous SCI/SCE testing) Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing)
      Inter-station difference ΔE * from < 0.15
      Dimensions 370*300*200mm
      Weight Approx. 9.6kg About 9.6kg
      Power DC 24V, 3A power adapter Power
      Lighting source life 5 years more than 3 million measurements More than 3 million measurements in 5 years
      Display TFT true color 7inch, capacitive touch screen TFT true color 7inch, capacitive touch screen
      Data Interface USB, print serial port
      Data storage 1000 master standards, 20,000 samples (SCI/SCE counts as one data)
      Operating language Simplified Chinese, English, Traditional Chinese Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish)
      Operating conditions 0~40℃(32~104°F)
      Storage environment -20~50℃
      Standards CIE No.15,GB/T 3978,GB 2893,GB/T   18833,ISO7724/1,ASTM E1164,DIN5033 Teil7
      Spectral reflectance repeability Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.05%)
      Sexual repeability 2 Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.01 (after the instrument is preheated and corrected, the average value of the whiteboard is measured 30 times at intervals of 5s)
      Sexual repeability 3 Spectral transmittance: Φ25.4mm/SCI, standard deviation within 0.06% (400~700nm: within 0.06%)
      Sexual repeability 4 Chromatic value: Φ25.4mm/SCI, ΔE * ab standard deviation within 0.015 (after the instrument is preheated and corrected, the average value of the whiteboard is measured 30 times at intervals of 5s)

      Friendly reminder: This page is a comparison of 3NH YS6003,3NH TS8216(Φ0.5mm).NBCLab only provides you with the similarities and differences of the product in the model and specifications.

      For more information about 3NH YS6003,3NH TS8216(Φ0.5mm)similarities and differences, please refer to the NBCLab product details.