![]() Model selection comparator
If you have any questions, please click below
|
![]() CHNSpec CS-600B Colorimeter
21500.0 RMB
ChinaDetail
|
![]() 3NH YS3060 color reader
Login
ChinaDetail
|
|---|
| Type | Portable | Portable | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F4mm | F4mm F8mm | |||
| Light source | LED light source | LED light source UV light source | |||
| Integrating sphere | ≤ F40mm | > F40mm | |||
| Color Repeatability | ≤0.03 | ≤0.03 | |||
| Aperture Shape | plane curved surface | plane curved surface | |||
| software | computer software | computer software | |||
| Special features | Fluorescence measurement | ||||
| Lighting method | D/8 (Scattering Light source, 8 degree Viewing Angle), SCI (including specular reflection component)/SCE (excluding specular reflection component) synchronous measurement function | D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; conforms to CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |||
|---|---|---|---|---|---|
| Sensors | Dual Path Array Sensors | 256 pixel dual array CMOS image sensor | |||
| Available Light Sources | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30.DLF,NBF,TL83,TL84.U35 | ||||
| Measurement time | 0.5sAbout 2s | Approximately 1.0s (approximately 2.6s for simultaneous SCI/SCE testing) | |||
| Measurement caliber | Φ4mm | Dual diameter: MAV: φ 8mm; SAV: φ 4mmMAV:Φ10mm;SAV:Φ5mm | |||
| Spectroscopic reflectance Repeatability | Standard deviation within 0.08% | ||||
| Operating language | Chinese, English | ||||
| Interface | USB, Bluetooth (customizable) | ||||
| Viewing Angle | CIE 2°/10° | CIE 2°/10° | |||
| Lighting source | CLEDs (Full Band Equalized Led Light sources) | ||||
| Color difference formula | delta E * ab, delta E * CH, delta E * uv, delta E * cmc (2:1), delta E * cmc (1:1), delta E * 94, delta E * 00, delta Eab (Hunter), 555 shade classification | ||||
| data storage | 20,000 pieces of test data | 1000 master standards, 28000 samples (one data can include SCI/SCE at the same time) | |||
| Power supply Voltage | Unmountable lithium battery pack, dedicated DC adapter | ||||
| display mode | Light spectrum chart/data, sample chromatic value, color difference value, pass/fail result, Color bias, display measurement area, historical data color simulation, manual input standard sample, generate test report | Light spectrum/data, sample chromatic values, color difference values/plots, pass/fail results, Color bias | |||
| Operating environment | 0-45 ℃, Relative Humidity 80% or less (at 35 ℃), no condensation | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m | |||
| Storage environment | -25~ 55 ℃, Relative Humidity 80% or less (at 35 ℃), no water condensation | -20~50 ℃, 0~85% RH (no condensation) | |||
| Dimensions | 181*73*112mm | 184*77*105mm | |||
| Weight | About 550g (without battery) | Approx. 600g | |||
| Integrating sphere size | Φ40mm | Φ48mm | |||
| Wavelength range | 400~700nm | 400~700nm | |||
| wavelength interval | 10nm | 10nm | |||
| Measurement range | 0~200% | ||||
| Resolution | 0.01% | ||||
| Inter-instrument Agreement | ΔE*ab<0.2 | ||||
| Display | Full color true color screen | ||||
| Chroma indicator | WI, YI, homochromatic index MI, colouring fastness, discoloration fastness, ISO luminance, 8 Glossiness, A density, T density, M density, E density, coverage, force, tinting strength, strength | WI, YI, TI, homochromatic index MI, colour fastness, color fastness, force, occlusion, 8 degree gloss | |||
| Light spectrum Bandwidth | 5nm | ||||
| Measurement time | 0.5sAbout 2s | Approximately 1.0s (approximately 2.6s for simultaneous SCI/SCE testing) | |||
| Color Space | CIE-L * a * b, L * C * h, L * u * v, XYZ, Yxy, reflectance, Hunter-lab, Munsell MI, CMYK. RGB. HSB | ||||
| Battery life | Charging, repeability, continuous measurement 10000 times, 7.4V/6000mAh | ||||
| Light source lifetime | 10 years 3 million times | ||||
| Color scheme | can be matched | ||||
| UV Light source | No UV Light source | ||||
| Repeatability of chromatic value | Delta E * ab 0.03, MAX Maximum 0.05 | ||||
Friendly reminder: This page is a comparison of CHNSpec CS-600B,3NH YS3060.NBCLab only provides you with the similarities and differences of the product in the model and specifications.