![]() Model selection comparator
If you have any questions, please click below
|
![]() hzaoc GDJW-010D Temperature Cycling Test Chamber
74600.0 RMB
ChinaDetail
|
![]() HUDA QD-E708-1000K60-X15 Rapid temperature change Test Chamber
218150.0 RMB
ChinaDetail
|
|---|
| Type | constant temperature | alternating | |||
|---|---|---|---|---|---|
| Min-TEMP | -60℃ | -60℃ | |||
| Max-TEMP | 150℃ | 150℃ | |||
| working Volume | 501~1000L | 501~1000L | |||
| Temperature range | -60~150℃ | -60~150℃ | |||
|---|---|---|---|---|---|
| Interior Volume | 1000L | 1000L | |||
| Heating rate | 1.0~3.0℃/min | ||||
| Temperature Uniformity | ≤±2.0℃ | ≤2℃ | |||
| Temperature fluctuation | ≤±0.5℃ | ||||
| Temperature deviation | ≤±2℃ | ±1℃ | |||
| Cooling rate | 0.7~1.0℃/min | ||||
| Timer | 0~999h | ||||
| Power | 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system | AC380V three-phase four-wire system + protective grounding N; Voltage allowable fluctuation range 10% V; Frequency allowable fluctuation range 50 +/- 0.5HZ; TN-S mode Power Supply or TT mode Power Supply; protective grounding resistance less than 4ΩLeakage protection, overload, short circuit and undercurrent protection | |||
| Total Power | 3 ~ 13.5KW | ||||
| Interior size | 1000*1000*1000mm | 1000*1000*1000mm | |||
| Dimensions | 1610*1560*1960mm | ≈1550*2330*2480mm | |||
| Inner chamber material | 1.0mmSUS304B stainless steel plate | ||||
| Enclosure Material | Cold rolled steel plate | ||||
| Thermal insulation material | Glass insulation cotton | ||||
| Observation window material | Multilayer Conductive Film Tempered Hollow Glass | ||||
| Observation window size | 200×300mm | ||||
| test hole | 50mm | ||||
| Air supply method | Upper air supply and lower air return method | ||||
| Heating system | Porcelain rack nickel-chromium wire electric heater | Nickel alloy heating pipe, Circulating Fan, P.I.D control heating | |||
| Standards | GB/T2423.1-2001、GB/T2423.2-2001、GB/T10592-2008、GB/T11158-89、GB/T10589-89、IEC68-2-1 | ||||
| Environment temperature | 5 ℃~ + 28 ℃ (average temperature within 24 hours ≤ 28 ℃) | ||||
| Environment humidity | ≤85%R.H | ||||
| Power | 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system | AC380V three-phase four-wire system + protective grounding N; Voltage allowable fluctuation range 10% V; Frequency allowable fluctuation range 50 +/- 0.5HZ; TN-S mode Power Supply or TT mode Power Supply; protective grounding resistance less than 4ΩLeakage protection, overload, short circuit and undercurrent protection | |||
| Water source requirements | Deionized water or purified water | ||||
Friendly reminder: This page is a comparison of hzaoc GDJW-010D,HUDA QD-E708-1000K60-X15.NBCLab only provides you with the similarities and differences of the product in the model and specifications.