      hzaoc GDJW-100D Temperature Cycling Test Chamber
      43700.0 RMB
      ChinaChina
      Detail
      hzaoc GDJW-50D Temperature Cycling Test Chamber
      39800.0 RMB
      ChinaChina
      Detail
      Model comparison
      Type constant temperature constant temperature
      Min-TEMP -60℃ -60℃
      Max-TEMP 150℃ 150℃
      working Volume ≤100L ≤100L
      Parameter comparison
      Temperature range -60~150℃ -60~150℃
      Interior Volume 100L 50L
      Heating rate 1.0~3.0℃/min 1.0~3.0℃/min
      Temperature Uniformity ≤±2.0℃ ≤±2.0℃
      Temperature fluctuation ≤±0.5℃ ≤±0.5℃
      Temperature deviation ≤±2℃ ≤±2℃
      Cooling rate 0.7~1.0℃/min 0.7~1.0℃/min
      Timer 0~999h 0~999h
      Power 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system
      Total Power 3 ~ 13.5KW 3 ~ 13.5KW
      Interior size 400*500*500mm 320*350*450mm
      Dimensions 1030*1020*1470mm 950*870*1420mm
      Inner chamber material 1.0mmSUS304B stainless steel plate 1.0mmSUS304B stainless steel plate
      Enclosure Material Cold rolled steel plate Cold rolled steel plate
      Thermal insulation material Glass insulation cotton Glass insulation cotton
      Observation window material Multilayer Conductive Film Tempered Hollow Glass Multilayer Conductive Film Tempered Hollow Glass
      Observation window size 200×300mm 200×300mm
      test hole 50mm 50mm
      Air supply method Upper air supply and lower air return method Upper air supply and lower air return method
      Heating system Porcelain rack nickel-chromium wire electric heater Porcelain rack nickel-chromium wire electric heater
      Standards GB/T2423.1-2001、GB/T2423.2-2001、GB/T10592-2008、GB/T11158-89、GB/T10589-89、IEC68-2-1 GB/T2423.1-2001、GB/T2423.2-2001、GB/T10592-2008、GB/T11158-89、GB/T10589-89、IEC68-2-1
      Environment temperature 5 ℃~ + 28 ℃ (average temperature within 24 hours ≤ 28 ℃) 5 ℃~ + 28 ℃ (average temperature within 24 hours ≤ 28 ℃)
      Environment humidity ≤85%R.H ≤85%R.H
      Power 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system 380V±10%AC380 (± 10%) V/50HZ three-phase five-wire system
      Water source requirements Deionized water or purified water Deionized water or purified water